Evaluation of cytotoxicity and physicochemical properties of calcium silicate-based endodontic sealer MTA Fillapex.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Silva Emmanuel J N L, Rosa Tiago P, Herrera Daniel R, Jacinto Rogério C, Gomes Brenda P F A, Zaia Alexandre A
Аннотация
INTRODUCTION: The aim of the study was to evaluate the cytotoxicity, radiopacity, pH, and flow of a calcium silicate-based and an epoxy resin-based endodontic sealer, MTA Fillapex (Angelus, Londrina, PR, Brazil) and AH Plus (Dentsply, Konstanz, Germany), respectively.
METHODS: Cytotoxicity, radiopacity, and flow evaluation were performed following ISO requirements. The pH level was measured at periods of 3, 24, 72, and 168 hours. Cytotoxicity was evaluated by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide assay to check the Balb/c 3T3 cells viability at 1- to 4-week periods. Data were statistically analyzed by analysis of variance and the Tukey test with a significance level of 5%.
RESULTS: In all tested periods, MTA Fillapex was more cytotoxic than AH Plus (P < .05). Although AH Plus presented higher radiopacity than MTA Fillapex (P < .05), both sealers showed minimum required values. MTA Fillapex presented alkaline pH in all experimental times, whereas AH Plus cement showed a slightly neutral pH and a flow significantly lower than that of MTA Fillapex (P < .05).
CONCLUSIONS: Although MTA Fillapex was more cytotoxic than AH Plus, it showed suitable physicochemical properties for an endodontic sealer.
METHODS: Cytotoxicity, radiopacity, and flow evaluation were performed following ISO requirements. The pH level was measured at periods of 3, 24, 72, and 168 hours. Cytotoxicity was evaluated by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide assay to check the Balb/c 3T3 cells viability at 1- to 4-week periods. Data were statistically analyzed by analysis of variance and the Tukey test with a significance level of 5%.
RESULTS: In all tested periods, MTA Fillapex was more cytotoxic than AH Plus (P < .05). Although AH Plus presented higher radiopacity than MTA Fillapex (P < .05), both sealers showed minimum required values. MTA Fillapex presented alkaline pH in all experimental times, whereas AH Plus cement showed a slightly neutral pH and a flow significantly lower than that of MTA Fillapex (P < .05).
CONCLUSIONS: Although MTA Fillapex was more cytotoxic than AH Plus, it showed suitable physicochemical properties for an endodontic sealer.
Предметные рубрики MeSH
3T3 CellsAluminum CompoundsAnimalsCalcium CompoundsCell SurvivalChemical PhenomenaColoring AgentsContrast MediaDrug CombinationsEpoxy ResinsFibroblastsHydrogen-Ion ConcentrationMaterials TestingMiceMice, Inbred BALB COxidesRheologyRoot Canal Filling MaterialsSilicatesTetrazolium SaltsThiazolesTime Factors