MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2026.129938

Медицинская библиотека · Talanta · 2026

Highly sensitive determination of glutathione with a colorimetric sensor based on bimetallic Pt-Cu nanorods as peroxidase mimetics.

Zhou Jutao, He Junyi, Liu Binxia, Liu Runhong, Ouyang Kai, Xu Yubo, Cheng Jiaming, Li Dan, Yu Donghong, Cao Zhong

СтатьяПеревод в очереди

Аннотация

Developing novel noble-metal nanozymes with well-defined morphology and high catalytic activity for sensitive and convenient detection of disease biomarkers like glutathione (GSH) is one of the most challenging hotspots nowadays. Here, taking H2PtCl6 and CuCl2·2H2O as precursors, cetyltrimethylammonium bromide as a structure-directing agent, and arginine as a reducing agent, bimetallic platinum-copper nanorods (Pt-Cu NRs) were synthesized by using a simple and effective one-pot method. Comprehensive characterization confirms that Pt-Cu NRs exhibited high alloyed structure and superior peroxidase-like activity compared with other shaped materials. Leveraging this performance, Pt-Cu NRs were then successfully employed to construct a highly sensitive colorimetric sensor for GSH. Interestingly, the principle is based on competitive depletion of hydroxy radicals (·OH) generated from the catalytic oxidation of H2O2 by Pt-Cu NRs nanozyme, where the competition occurs between GSH and the chromogenic substrate of 3,3',5,5'-tetramethylbenzidine (TMB). The colorimetric sensor showed good linear relationship between the absorbance response and GSH concentration in the range of 0.05∼50 μM and 50∼300 μM, with a detection limit of 10.5 nM. Notably, the proposed method possessed high selectivity and robust anti-interference capability, which has been successfully applied to the accurate determination of GSH in human serums from both healthy individuals and diseased patients, yielding results consistent with those obtained using commercial kits. These findings highlighted the sensor's significant application value in the fields of medical diagnosis and human health monitoring.

Для цитирования: Zhou Jutao, He Junyi, Liu Binxia, Liu Runhong, Ouyang Kai, Xu Yubo, Cheng Jiaming, Li Dan, Yu Donghong, Cao Zhong. Highly sensitive determination of glutathione with a colorimetric sensor based on bimetallic Pt-Cu nanorods as peroxidase mimetics.. Talanta. 2026. DOI: 10.1016/j.talanta.2026.129938.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.