m+Medelevator.RU
← Поиск публикаций
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2019

Factors in ProGlide® Vascular Closure Failure in Sheath Arteriotomies Greater than 16 French.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chen I-Ming, Lee Tsung-Hsing, Chen Po-Lin, Shih Chun-Che, Chang Hsiao-Hunag

Аннотация

OBJECTIVES: The ProGlide® vascular closure device (Abbott Vascular, Redwood City, CA, USA) is approved for the closure of arterial punctures (typically 5-21 Fr sheath; maximum outer diameter, 26 Fr). However, a failure rate of about 2-8% is reported. This study was conducted to analyse factors predisposing to failure when the devices were used for the closure of large hole (16-26 Fr) arteriotomies, and to determine the predictive cut off values of predisposing factors.

METHODS: In this retrospective study, the ProGlide® device was used to achieve vascular access site closure in 458 patients undergoing repair of abdominal aortic aneurysm, thoracic aortic aneurysm, type B aortic dissection, or transcatheter aortic valve implantation. The primary endpoint was device failure, defined as inability to achieve common femoral artery (CFA) closure; successful repair, development of acute lower limb ischaemia and haemodynamic compromise; or delayed pseudoaneurysm formation during the follow up period, requiring open repair.

RESULTS: Overall, ProGlide® failure occurred in 7.6% of cases. Factors that predisposed to failure included a history of peripheral arterial disease (PAD) (p < .001), the presence of CFA calcification (p < .001), the depth of the skin puncture site ≥ 33 mm (p < .001), body mass index (BMI) of ≥28.7 kg/m2 (p < .001), and use of sheath size ≥ 19 Fr (p < .001).

CONCLUSION: Factors such as BMI, history of PAD, the presence of CFA calcification, the depth of the skin puncture site, and sheath size are significantly associated with ProGlide® failure. Hence, careful patient and device selection and operating procedure are paramount to achieve successful outcomes.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты