Tissue motion annular displacement of the mitral valve using two-dimensional speckle tracking echocardiography predicts the left ventricular ejection fraction in normal children.

Black David E, Bryant Jen, Peebles Charles, Godfrey Keith M, Hanson Mark, Vettukattil Joseph J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The gold standard for determining the left ventricular ejection fraction is cardiac magnetic resonance imaging. Other parameters for determining the ejection fraction such as M-mode echocardiography are operator-dependant and often inaccurate. Assessment of the displacement of the mitral valve annulus using two-dimensional speckle tracking echocardiography may provide an accurate and simple method of determining the left ventricular ejection fraction in children.

METHOD: We retrospectively studied 70 healthy 9-year-old children with no history of cardiovascular disease who had been assessed using cardiac magnetic resonance imaging and two-dimensional transthoracic echocardiography. Mitral displacement was determined using the tissue motion annular displacement (TMAD) feature of Philips QLAB version 9. The midpoint displacement of the mitral valve was calculated, and the predicted left ventricular ejection fraction was compared with magnetic resonance imaging-derived and M-mode-derived ejection fractions.

RESULTS

The mean ejection fraction derived from magnetic resonance imaging (64.5 (4.6)) was similar to that derived from the TMAD midpoint (60.9 (2.7), p = 0.001) and the M-mode (61.9 (7), p = 0.012). The TMAD midpoint correlated strongly with the magnetic resonance imaging-derived ejection fraction (r = 0.69, p < 0.001), as did the predicted fraction (r = 0.67, p < 0.001). The M-mode ejection fraction showed a poor linear correlation with both magnetic resonance imaging-derived and TMAD-derived fractions (r = 0.33 and 0.04, respectively).

CONCLUSION

TMAD of the mitral valve is a simple, effective, and highly reproducible method of assessing the ejection fraction in normal children. It shows a strong linear correlation with magnetic resonance imaging-derived ejection fraction and is superior to M-mode-derived ejection fractions.

Для цитирования: Black David E, Bryant Jen, Peebles Charles, Godfrey Keith M, Hanson Mark, Vettukattil Joseph J. Tissue motion annular displacement of the mitral valve using two-dimensional speckle tracking echocardiography predicts the left ventricular ejection fraction in normal children.. Cardiology in the young. 2013. DOI: 10.1017/s1047951113000863.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.