Cost impact of monitoring exhaled nitric oxide in asthma management.
Аннотация
BACKGROUND
Asthma guidelines recommend periodic assessment of impairment and risk factors to prevent exacerbations, which can lead to hospitalization and increased health care utilization and cost. According to recent meta-analysis data, fractional exhaled nitric oxide (FeNO) monitoring is associated with a 40-50% reduction in the risk of exacerbations.
OBJECTIVE
Cost modeling of these data indicates the potential for significant cost savings with FeNO use. Therefore, we attempted to verify this potential for cost savings within a real-world data base of Medicare beneficiaries.
METHODS
This retrospective observational study investigated asthma-related claims from a Medicare data base. Beneficiaries were included who had 2 years of records after an asthma-related inpatient hospitalization (IP) or emergency department (ED) claim. A case-crossover analysis was completed of asthma-related IP or ED events before and after FeNO use during the 2-year study period.
RESULTS
Of the 5911 asthma beneficiaries who met the inclusion criteria within the data base, 101 had an FeNO test during the 2-year study period. During the period before FeNO use, 98 of 101 (97%) beneficiaries had an asthma-related IP or ED event compared with 46 of 101 (46%) during the FeNO period. Asthma-related IP or ED claims and charges per beneficiary per day during the period before FeNO were 0.004 and $16.21 compared with 0.002 and $6.46 during the FeNO period (p = 0.0433 and p = 0.0133, respectively).
CONCLUSION
FeNO monitoring in beneficiaries with a history of exacerbations was associated with a substantial reduction in asthma-related IP and ED claims and charges. These data supported cost modeling estimates and demonstrated that FeNO use in asthma management was associated with significant cost savings.