MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ibd/izab315

Медицинская библиотека · Inflammatory bowel diseases · 2022

Quantification of Mucosal Activity from Colonoscopy Reports via the Simplified Endoscopic Mucosal Assessment for Crohn's Disease.

Adler Jeremy, Eder Sally J, Gebremariam Acham, Moran Christopher J, Bass Lee M, Moses Jonathan, Lewis Jeffery D, Singer Andrew A M, Morhardt Tina L, Picoraro Joseph A, Cardenas Vanessa, Zacur George M, Colletti Richard B

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Endoscopic mucosal healing is the gold standard for evaluating Crohn's disease (CD) treatment efficacy. Standard endoscopic indices are not routinely used in clinical practice, limiting the quality of retrospective research. A method for retrospectively quantifying mucosal activity from documentation is needed. We evaluated the simplified endoscopic mucosal assessment for CD (SEMA-CD) to determine if it can accurately quantify mucosal severity recorded in colonoscopy reports.

METHODS

Pediatric patients with CD underwent colonoscopy that was video recorded and evaluated via Simple Endoscopic Score for CD (SES-CD) and SEMA-CD by central readers. Corresponding colonoscopy reports were de-identified. Central readers blinded to clinical history and video scoring were randomly assigned colonoscopy reports with and without images. The SEMA-CD was scored for each report. Correlation with video SES-CD and SEMA-CD were assessed with Spearman rho, inter-rater, and intrarater reliability with kappa statistics.

RESULTS

Fifty-seven colonoscopy reports were read a total of 347 times. The simplified endoscopic mucosal assessment for CD without images correlated with both SES-CD and SEMA-CD from videos (rho = 0.82, P < .0001 for each). The addition of images provided similar correlation. Inter-rater and intrarater reliability were 0.93 and 0.92, respectively.

CONCLUSIONS

The SEMA-CD applied to retrospective evaluation of colonoscopy reports accurately and reproducibly correlates with SES-CD and SEMA-CD of colonoscopy videos. The SEMA-CD for evaluating colonoscopy reports will enable quantifying mucosal healing in retrospective research. Having objective outcome data will enable higher-quality research to be conducted across multicenter collaboratives and in clinical registries. External validation is needed.

Для цитирования: Adler Jeremy, Eder Sally J, Gebremariam Acham, Moran Christopher J, Bass Lee M, Moses Jonathan, Lewis Jeffery D, Singer Andrew A M, Morhardt Tina L, Picoraro Joseph A, Cardenas Vanessa, Zacur George M, Colletti Richard B. Quantification of Mucosal Activity from Colonoscopy Reports via the Simplified Endoscopic Mucosal Assessment for Crohn's Disease.. Inflammatory bowel diseases. 2022. DOI: 10.1093/ibd/izab315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.