DOI 10.1016/j.gaitpost.2013.04.008

Медицинская библиотека · Gait & posture · 2013

Stride length-cadence relationship is disrupted in below-knee prosthesis users.

Howard Charla, Wallace Chris, Stokic Dobrivoje S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The aim of this study was to evaluate the linearity of the relationship between stride length and cadence (STRIDELC) over three self-selected speeds (normal, slow, fast) in below-knee prosthesis users (n=14, 11 men, mean age 43±12 years, mean time since amputation 9.2±6.9 years) in comparison to controls (n=20, 11 men, mean age 43±17 years). The step length-cadence relationship (STEPLC) was also calculated for the prosthetic and intact legs in prosthesis users and compared to the dominant leg of controls. The goodness of linear fit (R2) and slope over 3 speeds were used as outcome measures. Prosthesis users walked significantly slower than controls (slow-fast speed means 82-131 vs. 97-169 cm/s, respectively, ANOVA p<0.0001) due to both lower cadence (42-53 vs. 47-63 strides/min, p<0.0001) and shorter stride length (116-149 vs. 123-161 cm, p<0.0001). The R2 of STRIDELC relationship in below-knee prosthesis users (0.76±0.13) was significantly lower than in controls (0.91±0.03, p<0.001). The R2 values of STEPLC relationship between the prosthetic and intact legs in prosthesis users were correlated (r=0.85, p<0.001) and both (0.67±0.19, 0.58±0.21, respectively) were significantly smaller than in the dominant leg of controls (0.86±0.04, p<0.01). The slopes of STRIDELC and STEPLC were not different. The R2 of 0.84 for STRIDELC best discriminated prosthesis users from controls with high sensitivity (71%) and specificity (95%). The results indicate that coupling between stride/step length and cadence is disturbed in prosthesis users. Upon further investigation, the goodness of linear fit may prove to be useful in assessing prosthetic design, optimizing prosthetic fit, and predicting clinical outcomes.

Для цитирования: Howard Charla, Wallace Chris, Stokic Dobrivoje S. Stride length-cadence relationship is disrupted in below-knee prosthesis users.. Gait & posture. 2013. DOI: 10.1016/j.gaitpost.2013.04.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.