Occupational PFAS burden in German firefighters: Associations with aqueous film-forming foam contact frequency.

Rengelshausen Jens, Sauer Daniel, Esser Andre, Fraune Ellen, Safavi Maryam, Kraus Thomas, Schettgen Thomas, Ziegler Patrick

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Per- and polyfluoroalkyl substances (PFAS) are highly persistent and bioaccumulative chemicals used in numerous industrial applications, including aqueous film-forming foams (AFFF). Human PFAS exposure has been linked to dyslipidemia, reduced vaccine antibody responses, developmental effects and potential carcinogenicity.

OBJECTIVE

To determine whether firefighters with frequent occupational AFFF contact exhibit higher internal PFAS concentrations than firefighters with little or no foam exposure.

METHODS

In this observational study, 140 professional and avocational firefighters from five fire departments in the German Rhineland region were enrolled. Plasma concentrations of 27 PFAS were quantified using online SPE-LC/MS/MS. Participants completed a structured questionnaire capturing demographic characteristics, occupational history, AFFF contact frequency and potential confounders. Statistical analyses were performed using Generalized Linear Models (GLM) adjusted for relevant covariates.

RESULTS

Six PFAS (PFHxS, PFHpS, PFOA, PFOS, PFNA and PFDA) were detected in all participants. Firefighters reporting more than 10 lifetime AFFF contacts had higher European Food Safety Authority (EFSA) sum (PFHxS + PFOA + PFOS + PFNA) concentrations (mean 5.69 ± 4.19 μg/L) than those with ≤10 contacts (mean 3.79 ± 1.73 μg/L). Age was positively associated with PFAS levels, whereas regular blood donation was associated with lower concentrations. BMI and ski-wax exposure showed no significant associations.

CONCLUSIONS

Frequent occupational AFFF contact is associated with elevated internal PFAS concentrations in firefighters suggesting an exposure-biomarker relationship. While measured levels generally remain below international firefighter reference values, several surpassed the HBM-I health based guidance values of the German Human Biomonitoring commission. These findings highlight the need for further investigations into long-term health risks in occupationally exposed populations.

Для цитирования: Rengelshausen Jens, Sauer Daniel, Esser Andre, Fraune Ellen, Safavi Maryam, Kraus Thomas, Schettgen Thomas, Ziegler Patrick. Occupational PFAS burden in German firefighters: Associations with aqueous film-forming foam contact frequency.. International journal of hygiene and environmental health. 2026. DOI: 10.1016/j.ijheh.2026.114848.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.