Effectiveness and safety of the MiniMed™ 780G in newly diagnosed adolescents with type 1 diabetes: an observational real-world study.

Mameli Chiara, Sodero Roberta, Gaudenzi Francesca, Redaelli Francesca Chiara, Hajro Adelina, Petitti Agnese, Lauriola Federico, Panero Benedetta, Ippoliti Anna, Chiarelli Francesco, Zuccotti Gianvincenzo

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Evidence on starting advanced hybrid closed-loop systems (AHCL) at type 1 diabetes (T1D) onset in adolescents is limited. We evaluated the effectiveness and safety of very-early initiation of the MiniMed™ 780G advanced hybrid closed-loop system in newly diagnosed adolescents with T1D.

METHODS

This single-center, longitudinal, real-world observational study included adolescents aged 10–19 years who initiated MiniMed™ 780G within 30 days of T1D diagnosis (April 2023–January 2025) as standard of care. Clinical data and CareLink-derived continuous glucose monitoring (CGM) metrics were collected at pump placement (T0) and after 15 days (T1), 1 month (T2), 2 months (T3), 3 months (T4), and 6 months (T5). Outcomes included glycemic metrics (mean sensor glucose, time in range [TIR] 70–180 mg/dL, time in tight range [TITR] 70–140 mg/dL, time above range [TAR] > 180 mg/dL, time below range [TBR] < 70 mg/dL, coefficient of variation [CV], glucose management indicator [GMI]), system use (sensor wear, SmartGuard™ time), insulin delivery patterns, and safety events (severe hypoglycemia requiring glucagon, diabetic ketoacidosis [DKA]).

RESULTS

Eleven adolescents (72.7% male; mean age 11.63 ± 1.51 years) were enrolled; 72.7% presented with DKA at diagnosis. Mean glycated hemoglobin (HbA1c) at T0 was 11.71 ± 1.61% (102.18 ± 17.96 mmol/mol); HbA1c improved to 6.59 ± 0.79% at 3 months and 6.64 ± 0.46% at 6 months. Median time from diagnosis to pump start was 9 days (interquartile range [IQR] 6–20). CGM outcomes were excellent: median TIR remained high (90% at T0; 84% at T5), with very low hypoglycemia exposure (mean TBR: 2.00 ± 2.14% at T0; 1.09 ± 0.83% at T5) and mean GMI consistently < 7% (6.56 ± 0.41% at T0; 6.71 ± 0.38% at T5). Engagement was strong, with high sensor use and sustained SmartGuard™ utilization (> 98% median after T1). No severe hypoglycemia or DKA episodes occurred during 6 months of follow-up.

CONCLUSIONS

Early initiation of the MiniMed™ 780G within the first month after T1D onset in adolescents was associated with rapid achievement of CGM targets, marked HbA1c improvement, and an excellent short-term safety profile, supporting early AHCL use at disease onset.

Для цитирования: Mameli Chiara, Sodero Roberta, Gaudenzi Francesca, Redaelli Francesca Chiara, Hajro Adelina, Petitti Agnese, Lauriola Federico, Panero Benedetta, Ippoliti Anna, Chiarelli Francesco, Zuccotti Gianvincenzo. Effectiveness and safety of the MiniMed™ 780G in newly diagnosed adolescents with type 1 diabetes: an observational real-world study.. Endocrine. 2026. DOI: 10.1007/s12020-026-04646-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.