MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-026-13071-2

Медицинская библиотека · Surgical endoscopy · 2026

Intraoperative spectral imaging versus ICG fluorescence for gastric conduit viability in esophagectomy.

Winne Jens De, Vanommeslaeghe Hanne, Babin Danilo, Luong Hiep, Luthman Siri, Van Daele Elke, Ceelen Wim

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Anastomotic leakage remains a critical complication following esophagectomy, occurring in 8-20% of patients. While indocyanine green fluorescence imaging (ICG-FI) is commonly used to assess perfusion, it requires dye injection and does not directly measure tissue metabolism. This study evaluates a real-time, contrast-free spectral imaging (SI) system for quantifying gastric conduit oxygenation ( StO 2 ) and compares its performance to ICG-FI.

METHODS

Intraoperative SI was successfully performed in 33 patients undergoing laparoscopic Ivor Lewis esophagectomy using a video-rate snapshot spectral camera, acquiring 16 spectral bands in the 460-600 nm range. A deep learning model estimated StO 2 of the gastric conduit and quantitative perfusion metrics were derived from ICG-FI time-intensity curves. Local capillary lactate levels were measured as a physiological reference for tissue hypoxia. Statistical analyses compared StO 2 and ICG-FI metrics.

RESULTS

SI successfully differentiated well-perfused from ischemic tissue (median StO 2 : 69.16 % vs. 31.58 % , p < 0.001). The estimated StO 2 showed a strong negative correlation with local capillary lactate (r=-0.72, p < 0.001). While quantitative ICG-FI metrics ( T 1 / 2 and AUC 50 % ) revealed significantly reduced perfusion at the anastomosis site compared to well-perfused tissue (p < 0.001), they showed only a moderate correlation with StO 2 (r=0.50, p < 0.001). Notably, in a patient who developed anastomotic leakage, both modalities detected ischemia intraoperatively, but they show different transition borders, with SI indicating a more extensive hypoxic area than ICG-FI.

CONCLUSION

Snapshot SI provides a real-time, objective assessment of tissue oxygenation without the need for contrast agents. Its strong correlation with lactate suggests it may offer potential complementary value to dye-based perfusion imaging, potentially improving anastomotic site selection, although outcome-based validation studies in larger cohorts are needed.

Для цитирования: Winne Jens De, Vanommeslaeghe Hanne, Babin Danilo, Luong Hiep, Luthman Siri, Van Daele Elke, Ceelen Wim. Intraoperative spectral imaging versus ICG fluorescence for gastric conduit viability in esophagectomy.. Surgical endoscopy. 2026. DOI: 10.1007/s00464-026-13071-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление