DOI 10.1007/s00701-026-06921-4
Dangers of orbital retraction in transorbital neuroendoscopic surgery.
Аннотация
PURPOSE: This review summarizes the risks associated with orbital retraction in transorbital neuroendoscopic surgery (TONES) and proposes practical strategies to optimize surgical freedom while preserving visual function.
METHODS
A qualitative review synthesized through a systematic literature search of PubMed (MEDLINE) database. Studies involving human or cadaveric TONES and endoscopic transorbital approaches were reviewed.
RESULTS
Ten studies met inclusion criteria, comprising cadaveric as well as human subjects. Virtual-reality and cadaveric models revealed that 10-11 mm of globe displacement provides adequate surgical freedom, whereas sustained retraction beyond approximately 15 mm results in steep rises in intraocular and intra-orbital pressure posing a higher risk of orbital compartment syndrome. Clinical reports link prolonged retraction to transient or permanent mydriasis, ocular hypotony, decompression retinopathy, and visual loss.
CONCLUSION
Orbital retraction is central to TONES but is the principal driver of ocular morbidity. Based on the available evidence, retraction should be dynamic, gentle, and intermittent, with globe displacement generally limited to 10-12 mm. Apex-directed focal pressure should be avoided, and continuous monitoring of pupil and intraocular pressure is essential. Multidisciplinary protocols are recommended to standardize safe retraction practices while preserving the advantages of TONES.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.