Procedural and Clinical Outcomes According to Ultrasound-Guided Access in TAVI: A Propensity-Matched Comparative Subanalysis From the PULSE Registry.

Grundmann David, Rudolph Tanja, Adam Matti, Kellner Caroline, Bleiziffer Sabine, Braun Daniel, Tamm Alexander R, Meertens Max, Renker Matthias, Gmeiner Jonas, Sedaghat Alexander, Leistner David, Hamm Christian W, Wienemann Hendrik, Zapustas Norvydas, Juri Benjamin, Salem Mostafa, Benetti-Lehmann Roman, Dreger Henryk, Gossling Alina, Nahif Awesta, Blankenberg Stefan, Reichenspurner Hermann, Schofer Niklas, Schaefer Andreas, Popara Jasmin, Sudo Misumasa, Geyer Martin, Vorpahl Marc, Frank Derk, Potratz Max, Kim Won, Seiffert Moritz

СтатьяСравнительное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Access-related vascular and bleeding complications during transcatheter aortic valve implantation (TAVI) are associated with significant morbidity and mortality. Ultrasound-guided (USG) puncture may reduce the incidence of these adverse events, particularly in large-bore arterial access. However, large-scale data on this approach are limited, and it has not yet been fully implemented into standard clinical practice. We compared access-related vascular and bleeding complications in USG versus fluoroscopy-guided access from a large multicenter TAVI registry.

METHODS

The PULSE registry (Plug- or Suture-Based Vascular Closure After TAVI) retrospectively evaluated data of 9295 patients who underwent transfemoral TAVI at 10 high-volume German heart centers (2016-2021). USG and fluoroscopy-guided access were performed in 1992 (21.4%) and 7303 (78.6%) patients, respectively. Propensity score matching (1:1) yielded 895 matched pairs. The primary end point, a composite of minor and major vascular complications or bleeding type II-IV, was assessed according to Valve Academic Research Consortium definitions.

RESULTS

Patients in the USG and fluoroscopy-guided groups (median age, 81.9 [78.3-85.0] years; 47.8% female patients) showed well-balanced baseline characteristics. The overall risk profile was comparable (median EuroSCORE II: 3.2 versus 3.5; SD, 0.007 [-0.086 to 0.099]). The composite primary end point occurred less frequently in the USG group (11.7% versus 16.0%; odds ratio, 0.7; P=0.01), driven by lower rates of procedural bleeding (5.4% versus 9.2%; odds ratio, 0.56; P=0.002) and with lower rates of endovascular treatment (0.7% versus 2.5%; P=0.005).

CONCLUSIONS

In patients with transfemoral TAVI, USG access demonstrated lower rates of access-related vascular complications and type II-IV bleeding compared with fluoroscopy-guided access. Implementing USG puncture as the standard of care may improve access-related outcomes after TAVI.

Для цитирования: Grundmann David, Rudolph Tanja, Adam Matti, Kellner Caroline, Bleiziffer Sabine, Braun Daniel, Tamm Alexander R, Meertens Max, Renker Matthias, Gmeiner Jonas, Sedaghat Alexander, Leistner David, Hamm Christian W, Wienemann Hendrik, Zapustas Norvydas, Juri Benjamin, Salem Mostafa, Benetti-Lehmann Roman, Dreger Henryk, Gossling Alina, Nahif Awesta, Blankenberg Stefan, Reichenspurner Hermann, Schofer Niklas, Schaefer Andreas, Popara Jasmin, Sudo Misumasa, Geyer Martin, Vorpahl Marc, Frank Derk, Potratz Max, Kim Won, Seiffert Moritz. Procedural and Clinical Outcomes According to Ultrasound-Guided Access in TAVI: A Propensity-Matched Comparative Subanalysis From the PULSE Registry.. Circulation. Cardiovascular interventions. 2025. DOI: 10.1161/circinterventions.124.014771.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.