Randomized comparison of sheath size for coronary intervention: time to hemostasis and risk of radial artery occlusion.

Aagren Nielsen Christel G, Rasmussen Martin B, Rohde Pernille T, Jensen Rebekka Vibjerg, Jakobsen Lars, Støttrup Nicolaj Brejnholt, Veien Karsten T, Larsen Ellen N, Charlot Mette G, Terkelsen Christian J

СтатьяРандомизированное исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Transradial access is the preferred approach for coronary procedures due to lower complication rates compared to femoral access. However, minimizing equipment for radial access may further reduce bleeding and radial artery occlusion (RAO).

AIMS: This study assessed whether the use of 5F sheaths, compared to 6F sheaths, reduces time to hemostasis and the risk of RAO in patients undergoing diagnostic coronary angiography and/or coronary intervention.

METHODS

3600 patients were randomized to 5F or 6F sheaths, except when operators preferred 6F sheaths. TR-band deflation and removal times were recorded, and radial artery patency was assessed at discharge using the reverse Barbeau test, with Types C and D indicating RAO.

RESULTS

942 patients were randomized to 5F and 945 to 6F sheath. In 1713 patients, 6F sheaths were chosen up front by the operator. In intention-to-treat analysis no significant differences were observed between the randomized groups in time to TR-band removal (101 vs. 105 min, p = 0.07), or RAO (1.6 % vs. 2.1 %, p = 0.44). A significant crossover to 6F sheaths occurred in the 5F group. In as-treated analyses, TR-band removal times were shorter with 5F compared to 6F and operator-preferred 6F sheaths (98.5 min, 105 min, 111 min, P < 0.01). No significant differences in RAO risk were observed between groups (1.8 %, 1.9 %, 1.2 %, P = 0.34).

CONCLUSIONS

Although 5F sheaths reduced time to TR-band deflation and removal compared to 6F sheaths, no significant reduction in RAO was observed. High crossover rates suggest operator preference remains a key factor in sheath selection.

Для цитирования: Aagren Nielsen Christel G, Rasmussen Martin B, Rohde Pernille T, Jensen Rebekka Vibjerg, Jakobsen Lars, Støttrup Nicolaj Brejnholt, Veien Karsten T, Larsen Ellen N, Charlot Mette G, Terkelsen Christian J. Randomized comparison of sheath size for coronary intervention: time to hemostasis and risk of radial artery occlusion.. Cardiovascular revascularization medicine : including molecular interventions. 2025. DOI: 10.1016/j.carrev.2025.04.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.