MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.31199

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2024

Coagulation, fibrinolysis and platelet drop in patients undergoing transfemoral transcatheter aortic valve implantation.

Katayama Taiga, Yokoyama Naoyuki, Watanabe Yusuke, Koyama Shuhei, Kawashima Hideyuki, Hioki Hirofumi, Kozuma Ken

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic valve implantation (TAVI) leads to transient platelet activation and hypercoagulation status, resulting in thrombocytopenia.

AIMS: This study investigated the associations of coagulation/fibrinolysis status after transfemoral TAVI with valve type, post-TAVI thrombocytopenia, and complication of TAVI.

METHODS

Thrombin-antithrombin complex (TAT) and fibrin/fibrinogen degradation product (FDP) levels were measured before and 1 h, 1 day, and 2 days after TAVI. A percentage drop in platelet count (DPC) was determined from the pre- and lowest post-procedural values.

RESULTS

SAPIEN 3 (S3) was implanted in 158 patients and Evolut PRO/PRO+ (Evolut) in 117. Both TAT and FDP increased after TAVI. Pre-TAVI balloon dilatation was generally performed on patients undergoing implantation with Evolut. Peak TAT was then stratified into 4 quartiles (Q1 to Q4). Of all 275 study patients, 69 patients reached ultra-hypercoagulation status (Q4). S3, TAVI without pre-balloon dilatation, DPC and bleeding complications were significantly associated with the ultra-hypercoagulation status after TAVI. TAT was significantly greater 1 h after S3 implantation than Evolut (median [IQR], 43.1 [34.1-59.6] vs. 31.0 [25.0-40.4] ng/mL; p < 0.001). In contrast, FDP levels did not differ between the two at any measurement point. The difference in DPC among the peak TAT quartiles was statistically significant (p < 0.001). The occurrence of bleeding complications was significantly higher in the group with ultra-hypercoagulation status (5.8% vs. 1.0%, p = 0.036).

CONCLUSIONS

The increase in coagulation status and post-TAVI thrombocytopenia were significantly greater after S3 implantation. Ultra-hypercoagulation after TAVI was related to bleeding complications.

Для цитирования: Katayama Taiga, Yokoyama Naoyuki, Watanabe Yusuke, Koyama Shuhei, Kawashima Hideyuki, Hioki Hirofumi, Kozuma Ken. Coagulation, fibrinolysis and platelet drop in patients undergoing transfemoral transcatheter aortic valve implantation.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2024. DOI: 10.1002/ccd.31199.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.