INTRODUCTION

Access site complications remain common following atrial fibrillation (AF) catheter ablation. Femoral vascular closure devices (VCDs) reduce time to hemostasis compared with manual compression, although large-scale data comparing clinical outcomes between the two approaches are lacking.

METHODS

Two cohorts of patients undergoing AF ablation were identified from 36 healthcare organizations using a global federated research network (TriNetX): those receiving a VCD for femoral hemostasis, and those not receiving a VCD. A 1:1 propensity score matching (PSM) model based on baseline characteristics was used to create two comparable cohorts. The primary outcome was a composite of all-cause mortality, vascular complications, bleeding events, and need for blood transfusion. Outcomes were assessed during early (within 7 days of ablation) and extended follow-up (within 8-30 days of ablation).

RESULTS

After PSM, 28 872 patients were included (14 436 in each cohort). The primary composite outcome occurred less frequently in the VCD cohort during early (1.97% vs. 2.60%, odds ratio (OR) 0.76, 95% confidence interval (CI) 0.65-0.88; p < .001) and extended follow-up (1.15% vs. 1.43%, OR 0.80, 95% CI 0.65-0.98; p = .032). This was driven by a lower rate of vascular complications during early follow-up in the VCD cohort (0.83% vs. 1.26%, OR 0.66, 95% CI 0.52-0.83; p < .001), and fewer bleeding events during early (0.90% vs. 1.23%, OR 0.73, 95% CI 0.58-0.92; p = .007) and extended follow-up (0.36% vs. 0.59%, OR 0.61, 95% CI 0.43-0.86; p = .005).

CONCLUSION

Following AF ablation, femoral venous hemostasis with a VCD was associated with reduced complications compared with hemostasis without a VCD.

Для цитирования: Mills Mark T, Calvert Peter, Lip Gregory Y H, Luther Vishal, Gupta Dhiraj. Outcomes of vascular closure devices for femoral venous hemostasis following catheter ablation of atrial fibrillation.. Journal of cardiovascular electrophysiology. 2024. DOI: 10.1111/jce.16345.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.