MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00015458.2018.1487189

Медицинская библиотека · Acta chirurgica Belgica · 2018

Transmural migration of azygous vein Hem-O-lok clip causing food bolus 3 months following uneventful minimally invasive oesophagectomy.

Kordzadeh Ali, Charalabopoulos Alexandros, Lorenzi Bruno

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Hem-o-lok clips are widely deployed in various laparoscopic and robotic operations. Their migration is not very common and majority of reported cases are limited to biliary, prostatic and vesico-urethral cases.

METHODS

Herein, we would like to report the first case of transmural migration of Hem-o-lok clip from azygous vein stump following totally minimally invasive two-stage oesophagectomy for squamous cell carcinoma of the distal oesophagus, into the gastric conduit 3-months following uneventful discharge. The patient presented with 5-days history of worsening dysphagia.

RESULTS

The subsequent gastroscopy revealed normal gastric conduit with two Hem-o-lok clips containing the azygous vein stump within its lumen at the level of the oesophago-gastric anastomosis, propagating a food bolus obstruction. The foreign body was successfully removed and the patient was discharged the same day without any complications at 5 months follow up.

CONCLUSION

Hem-o-lok clip migration trends to be a well-established event. However, their mechanism and exact incidence remains elusive to this date. To the best of our knowledge, their migration in oesophageal cancer surgery has not been reported.

Для цитирования: Kordzadeh Ali, Charalabopoulos Alexandros, Lorenzi Bruno. Transmural migration of azygous vein Hem-O-lok clip causing food bolus 3 months following uneventful minimally invasive oesophagectomy.. Acta chirurgica Belgica. 2018. DOI: 10.1080/00015458.2018.1487189.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.