Evaluation of renal circulation in heart failure using superb microvascular imaging, a microvascular flow imaging system.

Kikuchi Shohei, Kayama Kiyomi, Kawada Yu, Kitada Shuichi, Seo Yoshihiro

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Renal circulation evaluation is essential in understanding the cardiorenal relationship in heart failure (HF), and there is a growing interest in imaging techniques that visualize renal circulation. This study aimed to assess the effectiveness of superb microvascular imaging (SMI) in evaluating renal circulation in HF patients.

METHOD: The study included 71 HF patients undergoing cardiac catheterization. Prior to catheterization, renal ultrasound examinations were performed. A control group of 18 subjects without HF was also included. SMI was used to measure the vascular index (VI), which was calculated as the percentage of blood flow signal area in the region of interest. The intrarenal perfusion index (IRPI) was determined as a fluctuation index of VI, reflecting variations in the number of blood cells moving through renal tissue during the cardiac cycle.

RESULTS

Using the upper 95% confidence interval of IRPI (0.6) from the control group, HF patients were classified into two groups. Patients with IRPI > 0.6 showed a more congestive profile. Right atrial pressure and biphasic or monophasic Doppler intrarenal flow pattern were independent determinants of IRPI > 0.6. In addition, IRPI remained a significant predictor of estimated glomerular filtration rate (eGFR).

CONCLUSION

The parameter IRPI as variations in SMI signal during the cardiac cycle may be a useful evaluation method for renal perfusion impairment in HF.

Для цитирования: Kikuchi Shohei, Kayama Kiyomi, Kawada Yu, Kitada Shuichi, Seo Yoshihiro. Evaluation of renal circulation in heart failure using superb microvascular imaging, a microvascular flow imaging system.. Journal of medical ultrasonics (2001). 2024. DOI: 10.1007/s10396-023-01397-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.