MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/pcc.0000000000003326

Медицинская библиотека · Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2023

Acute Hemodynamics in the Fontan Circulation: Open-Label Study of Vasopressin.

Adamson Gregory T, Yu Jane, Ramamoorthy Chandra, Peng Lynn F, Taylor Anne, Lennig Michael, Schmidt Alexander R, Feinstein Jeffrey A, Navaratnam Manchula

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To describe the acute hemodynamic effect of vasopressin on the Fontan circulation, including systemic and pulmonary pressures and resistances, left atrial pressure, and cardiac index.

DESIGN

Prospective, open-label, nonrandomized study (NCT04463394).

SETTING

Cardiac catheterization laboratory at Lucile Packard Children's Hospital, Stanford.

PATIENTS: Patients 3-50 years old with a Fontan circulation who were referred to the cardiac catheterization laboratory for hemodynamic assessment and/or intervention.

INTERVENTIONS: A 0.03 U/kg IV (maximum dose 1 unit) bolus of vasopressin was administered over 5 minutes, followed by a maintenance infusion of 0.3 mU/kg/min (maximum dose 0.03 U/min).

MEASUREMENTS AND MAIN

RESULTS

Comprehensive cardiac catheterization measurements before and after vasopressin administration. Measurements included pulmonary artery, atrial, and systemic arterial pressures, oxygen saturations, and systemic and pulmonary flows and resistances. There were 28 patients studied. Median age was 13.5 (9.1, 17) years, and 16 (57%) patients had a single or dominant right ventricle. Following vasopressin administration, systolic blood pressure and systemic vascular resistance (SVR) increased by 17.5 (13.0, 22.8) mm Hg ( Z value -4.6, p < 0.001) and 3.8 (1.8, 7.5) Wood Units ( Z value -4.6, p < 0.001), respectively. The pulmonary vascular resistance (PVR) decreased by 0.4 ± 0.4 WU ( t statistic 6.2, p < 0.001), and the left atrial pressure increased by 1.0 (0.0, 2.0) mm Hg ( Z value -3.5, p < 0.001). The PVR:SVR decreased by 0.04 ± 0.03 ( t statistic 8.1, p < 0.001). Neither the pulmonary artery pressure (median difference 0.0 [-1.0, 1.0], Z value -0.4, p = 0.69) nor cardiac index (0.1 ± 0.3, t statistic -1.4, p = 0.18) changed significantly. There were no adverse events.

CONCLUSIONS

In Fontan patients undergoing cardiac catheterization, vasopressin administration resulted in a significant increase in systolic blood pressure, SVR, and left atrial pressure, decrease in PVR, and no change in cardiac index or pulmonary artery pressure. These findings suggest that in Fontan patients vasopressin may be an option for treating systemic hypotension during sedation or general anesthesia.

Для цитирования: Adamson Gregory T, Yu Jane, Ramamoorthy Chandra, Peng Lynn F, Taylor Anne, Lennig Michael, Schmidt Alexander R, Feinstein Jeffrey A, Navaratnam Manchula. Acute Hemodynamics in the Fontan Circulation: Open-Label Study of Vasopressin.. Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2023. DOI: 10.1097/pcc.0000000000003326.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.