DOI 10.1017/s1047951123001440

Медицинская библиотека · Cardiology in the young · 2023

Cardiac magnetic resonance haemodynamics in paediatric heart transplant patients: fick oximetry versus cardiac magnetic resonance phase contrast.

Schramm Jennifer, Cronin Ileen, McCarter Robert, Mandell Jason G, Downing Tacy, Kanter Joshua, Cross Russell, Olivieri Laura

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Lifetime radiation exposure for paediatric orthotopic heart transplant (OHT) patients is significant with cardiac catheterisation as the dominant source. Interventional cardiac magnetic resonance is utilised to obtain simultaneous, radiation-free haemodynamics and flow/function measurements. We sought to compare invasive haemodynamic measurements and radiation exposure in traditional cardiac catheterisation, to comprehensive interventional cardiac magnetic resonance.

METHODS

Twenty-eight OHT patients who underwent 67 interventional cardiac magnetic resonance procedures at Children's National Hospital were identified. Both invasive oximetry with peripheral oxygen saturation (Fick) and cardiac magnetic resonance phase contrast measurements of pulmonary and systemic blood flow were performed. Systemic and pulmonary blood flow from the two modalities was compared using Bland-Altman, concordance analysis, and inter-reader correlation. A mixed model was implemented to account for confounding variables and repeat encounters. Radiation dosage data were collected for a contemporaneous cohort of orthotopic heart transplant patients undergoing standard, X-ray-guided catheterisation.

RESULTS

Simultaneous cardiac magnetic resonance and Fick have poor agreement in our study based on Lin's correlation coefficient of 0.68 and 0.73 for pulmonary and systemic blood flow, respectively. Bland-Altman analysis demonstrated a consistent over estimation of cardiac magnetic resonance cardiac output by Fick. The average indexed dose area product for patients undergoing haemodynamics with endomyocardial biopsy was 0.73 (SD ±0.6) Gy*m2/kg. With coronary angiography added, the indexed dose area product was 14.6 (SD ± 7.8) Gy*m2/kg.

CONCLUSIONS

Cardiac magnetic resonancemeasurements of cardiac output/index in paediatric orthotopic heart transplant patients have poor concordance with Fick estimates; however, cardiac magnetic resonance has good internal validity and inter-reader reliability. Radiation doses are small for haemodynamics with biopsy and increase exponentially with angiography, identifying a new target for cardiac magnetic resonance imaging.

Для цитирования: Schramm Jennifer, Cronin Ileen, McCarter Robert, Mandell Jason G, Downing Tacy, Kanter Joshua, Cross Russell, Olivieri Laura. Cardiac magnetic resonance haemodynamics in paediatric heart transplant patients: fick oximetry versus cardiac magnetic resonance phase contrast.. Cardiology in the young. 2023. DOI: 10.1017/s1047951123001440.

Предметные рубрики MeSH