MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2022.05.015

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2022

A Survey of the Congenital Cardiac Anesthesia Society on the Use and Clinical Application of Near- Infrared Tissue Oximetry in Pediatric Cardiac Surgery.

Zaleski Katherine L, Staffa Steven J, Kussman Barry D

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To better understand the patterns of use and the perceived utility of tissue oximetry in pediatric cardiac surgery.

DESIGN

A voluntary 32-question Research Electronic Data Capture survey instrument was sent twice via e-mail to the entire Congenital Cardiac Anesthesia Society (CCAS) membership (January 13, 2021 and March 9,2021).

SETTING

International multi-institutional, universities, academic centers, and community hospitals.

PARTICIPANTS

CCAS members.

INTERVENTIONS: Not applicable.

MEASUREMENTS AND MAIN

RESULTS

The survey was completed by 185 of 1,131 members (16.4% response rate). The majority of respondents (93.5%) reported use of tissue oximetry, with 97.1% reporting use for cardiac surgery with cardiopulmonary bypass, 76.3% for cardiac surgery without cardiopulmonary bypass, 34.7% in the cardiac catheterization laboratory, and 39.3% for major noncardiac surgeries. Only 14.5% reported that their institution had a formal near-infrared spectroscopy/tissue oximetry-based protocol. The most common sensor placement configuration was bilateral cerebral. More than 90% of respondents reported having made a clinical management change based on tissue oximetry values, although there was variability as to when respondents would intervene. The majority of respondents agreed or strongly agreed that tissue oximetry adds diagnostic value to standard intraoperative monitors, validates clinical observations, and aids in guiding patient management. Most, however, felt that tissue oximetry alone is not enough to inform management changes.

CONCLUSIONS

Near-infrared spectroscopy-based tissue oximetry frequently used was by CCAS members, but with significant variations in clinical application.

Для цитирования: Zaleski Katherine L, Staffa Steven J, Kussman Barry D. A Survey of the Congenital Cardiac Anesthesia Society on the Use and Clinical Application of Near- Infrared Tissue Oximetry in Pediatric Cardiac Surgery.. Journal of cardiothoracic and vascular anesthesia. 2022. DOI: 10.1053/j.jvca.2022.05.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.