MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jum.15933

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2021

A Technique to Reduce the Early Recurrence of Intussusception in Ultrasound-Guided Hydrostatic Reduction.

Yu Feng, Chen Huanhua, Cao Xiaoqing, Mao Weihao, Jiang Shuanglan, Yao Zhiguang, Zhang Min

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Ultrasound-guided saline enema is highly successful in treating pediatric intussusception; however, early recurrence-within 48 hours-is possible. This study aimed to explore effective methods of reducing early recurrence.

METHODS

This study included patients aged 0 to 14 years diagnosed with ileocolic intussusception with a symptom duration of <48 hours from January 2019 to March 2021. The patients were divided into control and intervention groups. All patients received successful treatment with ultrasound-guided saline enema; however, in patients treated before January 4, 2020 (control group), the intestinal fluid was drained immediately, and in patients treated after January 4, 2020 (intervention group), the intestinal fluid was drained after 15 minutes of intestinal pressure maintenance. Early recurrence rates of the groups were compared.

RESULTS

Ileocolic intussusception was treated successfully by ultrasound-guided saline enema in 231 patients (116, control group;115, intervention group). The early recurrence rate in the intervention group (10%; 95% CI: 4.9-16.5) was numerically lower than that in the control group (19%; 95% CI: 12.3-27.3). No significant difference was observed in the number of recurrences per person between the groups (P = .448). Patients without early recurrence were older (P = .004) and received enemas of a shorter duration (P < .001) and lower pressure (P < .001) than patients without early recurrence.

CONCLUSIONS

Maintaining reduction pressure for 15 minutes after a successful ultrasound-guided saline enema may reduce the early recurrence of intussusception. A randomized controlled trial is needed because the intervention and control cohorts were most probably incomparable (due to the COVID-19 pandemic).

Для цитирования: Yu Feng, Chen Huanhua, Cao Xiaoqing, Mao Weihao, Jiang Shuanglan, Yao Zhiguang, Zhang Min. A Technique to Reduce the Early Recurrence of Intussusception in Ultrasound-Guided Hydrostatic Reduction.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2021. DOI: 10.1002/jum.15933.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.