MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.pmrj.2015.03.015

Медицинская библиотека · PM & R : the journal of injury, function, and rehabilitation · 2015

Optimal Elbow Angle for Sonographic Visualization of the Ulnar Collateral Ligament.

Lueders Daniel R, Pourcho Adam M, Sellon Jacob L, Dahm Diane L, Smith Jay

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To formally examine the sonographic appearance of the elbow ulnar collateral ligament (UCL) at 30° versus 70° of elbow flexion in asymptomatic baseball pitchers.

DESIGN

A prospective, cross-sectional design.

SETTING

Sports medicine clinic in a tertiary academic medical center.

PARTICIPANTS

Thirty asymptomatic adolescent baseball pitchers 13-18 years of age (mean 15.8 years), with at least 3 years of continuous pitching experience and no significant history of elbow pain or injury.

METHODS

Static sonographic images of the bilateral UCLs were obtained at 30° and 70° of elbow flexion by a single experienced examiner. Images were anonymized and randomized into a slide set. Three clinicians with different levels of ultrasound experience reviewed the static 30° and 70° images for each elbow and chose their preferred image based on UCL conspicuity. The clinicians reviewed a re-randomized slide set 1 week later. A different study co-investigator measured UCL cross-sectional area (CSA) on all images using ultrasound machine electronic calipers.

MAIN OUTCOME MEASURES: Preference for the sonographic conspicuity of the UCL at 30° versus 70° of elbow flexion, and UCL CSA at 30° versus 70° of flexion.

RESULTS

Each clinician demonstrated a significant preference for UCL images obtained at 70° of flexion when compared to those obtained at 30° (80.3% overall preference for 70°, P < .001). There was no statistically significant effect of clinician experience or arm dominance on image preference. The sonographically determined CSA of the UCLs were on average 1.4 mm(2) greater at 70° than at 30° of flexion (P < .001) when combining dominant and nondominant arms.

CONCLUSIONS

Static sonographic evaluation of the UCL at 70° of elbow flexion should be integrated into UCL imaging protocols. Furthermore, when performing sonographically guided procedures targeting the UCL, clinicians should consider positioning the elbow at >30° of flexion to optimize UCL conspicuity and CSA.

Для цитирования: Lueders Daniel R, Pourcho Adam M, Sellon Jacob L, Dahm Diane L, Smith Jay. Optimal Elbow Angle for Sonographic Visualization of the Ulnar Collateral Ligament.. PM & R : the journal of injury, function, and rehabilitation. 2015. DOI: 10.1016/j.pmrj.2015.03.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.