European radiology · 2010
Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lim Hyun Kyong, Lee Kyoung Ho, Kim So Yeon, Kim Kil Joong, Kim Bohyoung, Lee Hyunna, Park Seong Ho, Yanof Jeffrey H, Hwang Seung-Sik, Kim Young Hoon
Аннотация
OBJECTIVE: To determine whether the amount of tagged stool and fluid significantly affects the radiation exposure in low-dose screening CT colonography performed with an automatic tube-current modulation technique.
METHODS: The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI (vol)) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI (vol ) and the effect of ATT on image noise while adjusting for other variables including abdominal circumference.
RESULTS: CTDI (vol) varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI (vol) and ATT (p = 0.61). ATT did not significantly affect CTDI (vol) (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI (vol) (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38.
CONCLUSION: The amount of stool and fluid tagging does not significantly affect radiation exposure.
METHODS: The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI (vol)) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI (vol ) and the effect of ATT on image noise while adjusting for other variables including abdominal circumference.
RESULTS: CTDI (vol) varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI (vol) and ATT (p = 0.61). ATT did not significantly affect CTDI (vol) (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI (vol) (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38.
CONCLUSION: The amount of stool and fluid tagging does not significantly affect radiation exposure.