MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of heart valve disease · 2005

Stentless bioprostheses in small aortic roots: impact of patient-prosthesis mismatch on survival and quality of life.

Ennker Jürgen, Rosendahl Ulrich, Albert Alexander, Dumlu Ercan, Ennker Ina Carolin, Florath Ines

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM OF THE STUDY: Although stentless bioprostheses offer hemodynamic advantages, prosthetic valves of smaller size may provide less reduction of left ventricular hypertrophy and, therefore, affect survival and quality of life.

METHODS

A total of 303 patients (mean age 75 +/- 7 years) who underwent aortic valve replacement with the stentless Freestyle bioprostheses were followed up. The impact of projected indexed effective orifice area (IEOA) on survival and quality of life (QoL) was determined multivariately by Cox regression and logistic regression analysis.

RESULTS

Independent predictors of survival time were diabetes mellitus (p < 0.001), atrial fibrillation (p = 0.004), male gender (p = 0.015), peripheral vascular disease (p = 0.039), and patient-prosthesis mismatch (PPM, defined as projected IEOA < 0.75 cm2/m2) in patients with aortic regurgitation (p = 0.017). A history of congestive heart failure (p = 0.016), small body mass index (p = 0.01), age > 75 years (p = 0.002) and small projected IEOA (p = 0.016) were identified as predictors of impaired QoL.

CONCLUSION

PPM and small projected IEOA were identified as independent risk factors for impaired mid-term survival and QoL. As the occurrence of PPM was rare in total root replacements, and the implantation procedure did not increase the operative risk in the present patient population, the recommendation is made to consider this implantation technique if a small projected IEOA is expected.

Для цитирования: Ennker Jürgen, Rosendahl Ulrich, Albert Alexander, Dumlu Ercan, Ennker Ina Carolin, Florath Ines. Stentless bioprostheses in small aortic roots: impact of patient-prosthesis mismatch on survival and quality of life.. The Journal of heart valve disease. 2005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.