DOI 10.1097/icl.0000000000001262
Identify the Relationships Between Orthokeratology Lens Decentration and Myopia Control Efficacy in Children by Using Pentacam.
Аннотация
PURPOSE: To determine orthokeratology (ortho-k) lens decentration and its relationships with annual axial length (AL) changes in children treated with ortho-k.
METHODS
This retrospective study included children aged 9 to 15 years treated with ortho-k for at least 1 year. Lens decentration was measured using Pentacam based on the relative positions of the corneal thinnest point, pupil center, and visual center. Annual AL change was analyzed using regression models adjusted for age and target power.
RESULTS
In total, 71 eyes from 37 patients (mean age, 10.9 years) were included in the final analysis. The mean follow-up time was 35.0 months. The mean annual AL change was 0.11 mm. According to the customized formula based on the pupil or visual center, greater horizontal and vertical vectors and a larger total distance of decentration were associated with less annual AL change.
CONCLUSION
Greater temporal and inferior vectors, as well as a larger total distance of decentration, are associated with greater myopia control efficacy. These findings will help to facilitate the prescription and future design of ortho-k lenses to improve myopia control efficacy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.