Implantation of cardiac electronic devices in active COVID-19 patients: Results from an international survey.

Tovia-Brodie Oholi, Rav Acha Moshe, Belhassen Bernard, Gasperetti Alessio, Schiavone Marco, Forleo Giovanni Battista, Guevara-Valdivia Milton E, Ruiz David Valdeolivar, Lellouche Nicolas, Hamon David, Castagno Davide, Bellettini Matteo, De Ferrari Gaetano M, Laredo Mikael, Carvès Jean-Baptiste, Ignatiuk Barbara, Pasquetto Giampaolo, De Filippo Paolo, Malanchini Giovanni, Pavri Behzad B, Raphael Craig, Rivetti Luigi, Mantovan Roberto, Chinitz Jason, Harding Melissa, Boriani Giuseppe, Casali Edoardo, Wan Elaine Y, Biviano Angelo, Macias Carlos, Havranek Stepan, Lazzerini Pietro Enea, Canu Antonio M, Zardini Marco, Conte Giulio, Cano Óscar, Casella Michela, Rudic Boris, Omelchenko Alexander, Mathuria Nilesh, Upadhyay Gaurav A, Danon Asaf, Schwartz Arie Lorin, Maury Philippe, Nakahara Shiro, Goldenberg Gustavo, Schaerli Nicolas, Bereza Sergiy, Auricchio Angelo, Glikson Michael, Michowitz Yoav

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown.

OBJECTIVE

The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey.

METHODS

Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure.

RESULTS

The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe.

CONCLUSION

CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.

Для цитирования: Tovia-Brodie Oholi, Rav Acha Moshe, Belhassen Bernard, Gasperetti Alessio, Schiavone Marco, Forleo Giovanni Battista, Guevara-Valdivia Milton E, Ruiz David Valdeolivar, Lellouche Nicolas, Hamon David, Castagno Davide, Bellettini Matteo, De Ferrari Gaetano M, Laredo Mikael, Carvès Jean-Baptiste, Ignatiuk Barbara, Pasquetto Giampaolo, De Filippo Paolo, Malanchini Giovanni, Pavri Behzad B, Raphael Craig, Rivetti Luigi, Mantovan Roberto, Chinitz Jason, Harding Melissa, Boriani Giuseppe, Casali Edoardo, Wan Elaine Y, Biviano Angelo, Macias Carlos, Havranek Stepan, Lazzerini Pietro Enea, Canu Antonio M, Zardini Marco, Conte Giulio, Cano Óscar, Casella Michela, Rudic Boris, Omelchenko Alexander, Mathuria Nilesh, Upadhyay Gaurav A, Danon Asaf, Schwartz Arie Lorin, Maury Philippe, Nakahara Shiro, Goldenberg Gustavo, Schaerli Nicolas, Bereza Sergiy, Auricchio Angelo, Glikson Michael, Michowitz Yoav. Implantation of cardiac electronic devices in active COVID-19 patients: Results from an international survey.. Heart rhythm. 2021. DOI: 10.1016/j.hrthm.2021.10.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.