m+Medelevator.RU
← Поиск публикаций
Acta oncologica (Stockholm, Sweden) · 2025

Adaptation of dose-prescription for vestibular schwannoma radiosurgery taking body contouring method and heterogeneous material into account.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fager Marcus, Gubanski Michael, Carlsson Tedgren Åsa, Benmakhlouf Hamza

Аннотация

BACKGROUND: Majority of vestibular schwannoma (VS) patients have undergone gamma-knife radiosurgery (GKRS) with favorable results. Clinical evidence is derived from doses calculated with a type-a algorithm, which in this case assumes all material to be water. A type-b algorithm (Convolution algorithm [CA]) taking tissue heterogeneity into account is available. Historically, body contour is defined using a 16-point approximation, whereas modern softwares generate the body from Magnetic Resonance Imaging (MRI). The accuracy in dose-calculation algorithms (DCA) and contouring method (CM) will have a significant influence in the relation between clinical outcome and dosimetric data. The objective was to investigate the impact of DCA and CMs on dose distribution while preserving treatment conditions.

METHODS: Treatment plans for 16 VS patients were recalculated in terms of DCA and CM. The difference in the dose covering 99% of the VS (DVS99%) depending on CM and DCA was estimated. The difference in DVS99% was used to adopt the prescription of new CA-based plans. CA-plans were recalculated to TMR10 to evaluate clinical treatability, as clinical evidence is derived from TMR10-doses.

RESULTS: Both CM and DCA had a significant impact on the dose to VS and surrounding structures. CM altered the doses homogenously by 2.1-3.3%, whereas DCA heterogeneously by 5.0-10.7%. An increase of 9.1[8.1, 10.0]% was found for DVS99% and the CA-plans recalculated into TMR10 resulted in clinically treatable plans.

INTERPRETATION: We conclude that transferring to more modern algorithms that take tissue heterogeneity into account heterogeneously alter dose distributions. This work establishes a safe pathway to adopt prescription dose for VS while preserving clinical treatability.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты