DOI 10.1186/s12886-024-03409-6

Медицинская библиотека · BMC ophthalmology · 2024

Correlation analysis of angles κ and α with the refraction and anterior segment parameters in children.

Ye Yuhao, Zhao Yu, Zhang Zhe, Wei Ruoyan, Xian Yiyong, Huang Yangyi, Liu Fang, Xu Ye, Zhou Xingtao

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To investigate the correlation of angles α and κ with the refractive and biological parameters in children.

METHODS

This case-series study included 438 eyes of 219 children (males/females = 105/114, age: 3-15 years). Ocular biometric parameters, including axial length, corneal radius of curvature (CR), white-to-white distance (WTW), angle κ and angle α, were measured using IOL Master 700; auto-refraction were assessed under cycloplegia. The eyes were assigned to different groups based on CR, WTW, and gender to compare the angles α and κ, and analyze the correlations between the differences of biological parameters on angles α and κ.

RESULTS

The means of axial length, CR, WTW, angle α, and angle κ were 23.24 ± 1.14 mm, 7.79 ± 0.27 mm, 11.68 ± 0.41 mm, 0.45 ± 0.25 mm, and 0.27 ± 0.22 mm, respectively. Angle α was correlated with CR and WTW (fixed effect coefficient [FEC] = 0.237, p = 0.015; FEC = -0.109, p = 0.003; respectively), and angle κ also correlated with CR and WTW (FEC = 0.271, p = 0.003; FEC = -0.147, p < 0.001, respectively). Comparing subgroups, the large CR and small WTW group had larger angles α (0.49 ± 0.27 vs. 0.41 ± 0.21, p < 0.001; 0.46 ± 0.27 vs. 0.44 ± 0.21, p < 0.05, respectively) and κ (0.29 ± 0.25 vs. 0.24 ± 0.15, p < 0.01; 0.29 ± 0.25 vs. 0.26 ± 0.19, p < 0.05, respectively). The differences in interocular angles α and κ showed correlation with interocular WTW (r = - 0.255, p < 0.001; r = - 0.385, p < 0.001). Eyes with smaller WTW tended to have larger angle κ (0.28 ± 0.27 vs. 0.25 ± 0.15, p < 0.05).

CONCLUSION

The size of angle α/κ may be correlated to CR and WTW, and a larger WTW eye may suggest a smaller angle κ compared with the fellow eye.

Для цитирования: Ye Yuhao, Zhao Yu, Zhang Zhe, Wei Ruoyan, Xian Yiyong, Huang Yangyi, Liu Fang, Xu Ye, Zhou Xingtao. Correlation analysis of angles κ and α with the refraction and anterior segment parameters in children.. BMC ophthalmology. 2024. DOI: 10.1186/s12886-024-03409-6.