DOI 10.1016/s0002-9394(14)70988-2
Secondary posterior chamber intraocular lens implantation in pediatric patients.
Аннотация
PURPOSE: To report results of secondary posterior chamber intraocular lens (IOL) implantation in previously aphakic pediatric patients.
METHODS
In 19 pediatric patients, 19 aphakic eyes (11 after infantile and eight after traumatic cataract surgery) received secondary sulcus-fixated posterior chamber IOL implants.
RESULTS
Visual acuity of 20/40 or better was achieved with IOL implantation and overrefraction in three of 11 infantile (27%) and six of eight traumatic cataract patients (mean follow-ups, 18.1 months [range, 8 to 29 months] and 18.0 months [range, 6 to 28 months]), respectively. Eighteen of 19 patients (95%) demonstrated postoperative vision equal to or better than preoperative levels; 15 of 19 patients (79%) showed improved vision after IOL implantation. The mean +/- SD difference between actual and predicted postoperative refraction at 1 month was -0.97 +/- 0.96 diopter. Average refractive error at last examination was -0.40 +/- 2.43 diopters. Amblyopia therapy was performed in 14 patients. One IOL required repositioning 8 months postoperatively. Strabismus was present in 14 patients before and 13 patients after IOL implantation, requiring surgery in four patients.
CONCLUSIONS
Secondary IOL implantation can be performed successfully in carefully selected pediatric patients. Visual acuity results are better in eyes with a history of traumatic cataract and are influenced by patient compliance. The short-term risks of the procedure appear no greater than those of primary IOL implantation, and complications resemble those seen in adults.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.