MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2003.12.036

Медицинская библиотека · The Annals of thoracic surgery · 2004

Is a bicuspid aortic valve a risk factor for adverse outcome after an autograft procedure?

Bogers Ad J J C, Kappetein Arie-Pieter, Roos-Hesselink Jolien W, Takkenberg Johanna J M

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Recently, bicuspid aortic valve disease is posed to be a possible risk factor for dilatation of the pulmonary autograft.

METHODS

Analysis of all 123 patients in our prospective cohort with their native aortic valve in situ at the autograft procedure.

RESULTS

The bicuspid aortic valve group (n = 81) had more males (p = 0.05), prior cardiac surgery (p = 0.02), prior aortic valve balloon dilatation (p = 0.01), aortic stenosis (p = 0.03), and less deterioration of left ventricular function (p = 0.02) than the tricuspid group (n = 42). Hospital mortality occurred in 3 patients (bicuspid 2, tricuspid 1). The follow-up was 99% complete (median, 5.3 years; SD, 3.5; range, 0.1 to 13.4) with a total of 674 patient years. During follow-up 4 patients died (bicuspid 2, tricuspid 2). Overall survival was 95% (95% confidence interval [CI], 89% to 98%) at 5 and 10 years. Seven patients required reoperation for autograft failure, all structural. Freedom from autograft reintervention was 97% (95% CI, 92% to 100%) at 5 years and 89% (95% CI, 79% to 98%) at 10 years. There were no differences in outcome between the groups. Four patients required reoperation for allograft failure, all structural. Freedom from allograft reoperation was 99% (95% CI, 97% to 100%) at 5 years and 91% (95% CI, 82% to 100%) at 10 years. There was no difference between the groups.

CONCLUSIONS

An autograft procedure in patients with a bicuspid aortic valve is justified. Bicuspid aortic valve disease is not a contraindication for an autograft procedure. Patients with a bicuspid aortic valve will meet the limitations of the autograft procedure in the same frequency as the overall autograft population.

Для цитирования: Bogers Ad J J C, Kappetein Arie-Pieter, Roos-Hesselink Jolien W, Takkenberg Johanna J M. Is a bicuspid aortic valve a risk factor for adverse outcome after an autograft procedure?. The Annals of thoracic surgery. 2004. DOI: 10.1016/j.athoracsur.2003.12.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.