Filsoufi Farzan, Salzberg Sacha P, Coutu Marianne, Adams David H
Аннотация
PURPOSE: Significant functional tricuspid regurgitation should be corrected in patients undergoing surgery for left-sided valvular diseases. Several clinical studies have shown the superiority of the remodeling annuloplasty over other repair techniques. Herein we report our early experience with a new three-dimensional remodeling prosthetic ring (Edwards MC3 annuloplasty system [Edwards LifeSciences, Irvine, CA]).
DESCRIPTION: From June 2002 to November 2004, 75 patients with functional tricuspid regurgitation (mean, 3.1 +/- 0.9) underwent tricuspid valve repair with this new prosthesis. Concomitant procedures were mitral valve repair (70%), replacement (26%), aortic valve replacement (10%), coronary artery bypass grafting (13%), and left atrial maze (34%). Median predicted EuroScore mortality was 21% (r = 3 to 62).
EVALUATION: Operative mortality was 5.3% (n = 4). Pre-discharge echocardiography showed significant decrease in tricuspid regurgitation to 0.3 +/- 0.4 (p < 0.001). Forty-five patients had follow-up transthoracic echocardiography after a median of 16 months (range, 4 to 34) demonstrating a stable result (mean tricuspid regurgitation, 0.3 +/- 0.5). There were no cases of ring dehiscence, prosthetic ring endocarditis, or thromboembolic events.
CONCLUSIONS: This new three-dimensional ring is easy to implant, corrects tricuspid regurgitation effectively, and provides good short-term clinical and echocardiographic results. Long-term evaluation, however, is necessary to determine the stability of tricuspid valve repair using the MC3 annuloplasty system.
DESCRIPTION: From June 2002 to November 2004, 75 patients with functional tricuspid regurgitation (mean, 3.1 +/- 0.9) underwent tricuspid valve repair with this new prosthesis. Concomitant procedures were mitral valve repair (70%), replacement (26%), aortic valve replacement (10%), coronary artery bypass grafting (13%), and left atrial maze (34%). Median predicted EuroScore mortality was 21% (r = 3 to 62).
EVALUATION: Operative mortality was 5.3% (n = 4). Pre-discharge echocardiography showed significant decrease in tricuspid regurgitation to 0.3 +/- 0.4 (p < 0.001). Forty-five patients had follow-up transthoracic echocardiography after a median of 16 months (range, 4 to 34) demonstrating a stable result (mean tricuspid regurgitation, 0.3 +/- 0.5). There were no cases of ring dehiscence, prosthetic ring endocarditis, or thromboembolic events.
CONCLUSIONS: This new three-dimensional ring is easy to implant, corrects tricuspid regurgitation effectively, and provides good short-term clinical and echocardiographic results. Long-term evaluation, however, is necessary to determine the stability of tricuspid valve repair using the MC3 annuloplasty system.
Предметные рубрики MeSH
AdultAgedAged, 80 and overAortic ValveAtrial FibrillationCardiac Pacing, ArtificialComorbidityCoronary Artery BypassEquipment DesignFemaleFollow-Up StudiesHeart Valve Prosthesis ImplantationHospital MortalityHumansMaleMiddle AgedMitral ValveMultiple Organ FailurePostoperative ComplicationsProstheses and ImplantsProsthesis ImplantationRetrospective StudiesSeverity of Illness IndexTreatment OutcomeTricuspid Valve InsufficiencyUltrasonography