MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12659/ajcr.910861

Медицинская библиотека · The American journal of case reports · 2018

Eosinophilic Granulomatosis with Polyangiitis (EGPA) with an Unusual Manifestation of Mid-Ventricular Obstruction Caused by Endocardial Thrombus.

Ito Takahide, Fujita Shu-Ichi, Kanzaki Yumiko, Sohmiya Koichi, Hoshiga Masaaki

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND Eosinophilic granulomatosis with polyangiitis (EGPA) is a rare systemic vasculitis of unknown cause accompanied by prominent eosinophilia. Intracardiac thrombosis is one of the major cardiac complications in EGPA that may cause thromboembolism. CASE REPORT A 46-year-old male presenting with intermittent chest pain and numbness of the lower extremities was admitted to our center. His case was complicated by multiple brain infarcts and endocardial thrombosis in the left ventricle. A condition of restrictive cardiomyopathy was also found. After a thorough workup, he was diagnosed with antineutrophil cytoplasmic antibody (ANCA) positive EGPA. Interestingly, the thrombus was accompanied by a pressure gradient producing mid-ventricular obstruction. The patient improved reasonably with immunosuppression and anticoagulation treatment, in addition to heart failure treatment, and had a concomitant regression of the thrombus and reduction of the pressure gradient. CONCLUSIONS For an EGPA patient complicated by intraventricular obstruction caused by endocardial thrombosis, which could accelerate the release of the thrombus into the systemic circulation resulting in a life-threating condition, timely and aggressive measures against cardioembolic complications should be considered.

Для цитирования: Ito Takahide, Fujita Shu-Ichi, Kanzaki Yumiko, Sohmiya Koichi, Hoshiga Masaaki. Eosinophilic Granulomatosis with Polyangiitis (EGPA) with an Unusual Manifestation of Mid-Ventricular Obstruction Caused by Endocardial Thrombus.. The American journal of case reports. 2018. DOI: 10.12659/ajcr.910861.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.