m+Medelevator.RU
← Поиск публикаций
Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology · 2024

The impact of intravenous medetomidine and vatinoxan on echocardiographic evaluation of dogs with stage B1 mitral valve disease.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Välimäki E, Leppänen H, Turunen H, Raekallio M, Honkavaara J

Аннотация

INTRODUCTION/OBJECTIVE: The purpose of this study was to investigate the echocardiographic effects of intravenous medetomidine and vatinoxan in dogs with stage B1 mitral valve disease. We hypothesised medetomidine-vatinoxan would reduce the need for manual restraint during echocardiography without producing detrimental cardiovascular effects or echocardiographic changes.

ANIMALS: Twelve client-owned dogs with stage B1 mitral valve disease.

METHODS: A transthoracic echocardiographic examination was performed before and after sedation with intravenous medetomidine (10 μg/kg) and vatinoxan (200 μg/kg). Vital parameters were also recorded, and the level of sedation was assessed subjectively. The data were analysed with Student's t-tests with an alpha level of <0.05.

RESULTS: End-systolic volume and left ventricular systolic diameter increased (from 0.89 ± 0.19 mL/kg to 1.13 ± 0.29 mL/kg and 0.96 ± 0.12 cm to 1.10 ± 0.10 cm, respectively) and ejection fraction (from 66.33 ± 4.0% to 56.23 ± 9.54%) and fractional shortening (from 36.13 ± 5.42% to 27.24 ± 5.6%) decreased significantly after sedation. End diastolic volume, left ventricular diastolic diameter, and left atrial size remained statistically unchanged, while aortic (from 1.34 ± 0.2 m/s to 0.99 ± 0.14 m/s) and pulmonic (from 0.94 ± 0.16 m/s to 0.66 ± 0.15 m/s) velocities decreased significantly. No dogs had a mean arterial pressure below 65 mmHg. Sedation enabled echocardiographic examination without manual restraint. No adverse effects were observed with the dose studied.

CONCLUSIONS: Echocardiographic parameters were not completely comparable with the baseline values, which should be taken into consideration when evaluating dogs sedated with intravenous medetomidine-vatinoxan.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты