MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/opo.12698

Медицинская библиотека · Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2020

The diversified defocus profile of the near-work environment and myopia development.

Choi Kai Yip, Mok Angela Yuen-Ting, Do Chi-Wai, Lee Paul Hong, Chan Henry Ho-Lung

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To quantify the defocus characteristics in the near-work environment at home and investigate the relationship with subsequent myopia progression.

METHODS

Fifty subjects (aged 7-12 years) were recruited and followed for 1 year. The home near-work environment (writing desk) was measured at a baseline home-visit using the Kinect-for-Windows to capture a 3-dimensional image. The depth values of the image were then converted into scene defocus with respect to the subject's viewpoint. The defocus characteristics were quantified as the dioptric volume (the total amount of net defocus, or DV) and standard deviation of the defocus values (SDD ). Information on home size, time spent outdoors, and in front of a desk were also obtained. Univariate correlation, and multivariate regression were used to assess the association between myopia progression, defocus characteristics, and other co-variates.

RESULTS

The baseline spherical equivalent refraction (M) and refraction change over 1 year (∆M) were - 1.51 ± 2.02 D and - 0.56 ± 0.45 D respectively. DV was not significantly correlated with ∆M (Spearman's ρ = -0.25, p = 0.08), while SDD was negatively correlated to ∆M (Spearman's ρ = -0.42, p = 0.003). Although SDD was not a significant predictor in multivariate analysis, the regional DV at 15°-20° eccentricity was significant (p = 0.001). Home size (F2,50  = 7.01, p = 0.002) and time spent outdoors (Independent t = -2.13, p = 0.04) were also associated with ∆M, but not time spent in front of desk (Independent t = 0.78, p = 0.44).

CONCLUSION

The defocus profile in the home environment within the para-central field of view is associated with childhood refractive error development.

Для цитирования: Choi Kai Yip, Mok Angela Yuen-Ting, Do Chi-Wai, Lee Paul Hong, Chan Henry Ho-Lung. The diversified defocus profile of the near-work environment and myopia development.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2020. DOI: 10.1111/opo.12698.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.