Magnetic resonance imaging of muscle in congenital myopathies associated with RYR1 mutations.

Jungbluth Heinz, Davis Mark R, Müller Clemens, Counsell Serena, Allsop Joanna, Chattopadhyay Arijit, Messina Sonia, Mercuri Eugenio, Laing Nigel G, Sewry Caroline A, Bydder Graeme, Muntoni Francesco

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Mutations in the skeletal muscle ryanodine receptor (RYR1) gene are associated with a wide range of phenotypes, comprising central core disease and distinct subgroups of multi-minicore disease. We report muscle MRI findings of 11 patients from eight families with RYR1 mutations (n=9) or confirmed linkage to the RYR1 locus (n=2). Patients had clinical features of a congenital myopathy with a wide variety of associated histopathological changes. Muscle MR images showed a consistent pattern characterized by (a) within the thigh: selective involvement of vasti, sartorius, adductor magnus and relative sparing of rectus, gracilis and adductor longus; (b) within the lower leg: selective involvement of soleus, gastrocnemii and peroneal group and relative sparing of the tibialis anterior. Our findings indicate that patients with RYR1-related congenital myopathies have a recognizable pattern of muscle involvement irrespective of the variability of associated histopathological findings. Muscle MRI may supplement clinical assessment and aid selection of genetic tests particularly in patients with non-diagnostic or equivocal histopathological features.

Для цитирования: Jungbluth Heinz, Davis Mark R, Müller Clemens, Counsell Serena, Allsop Joanna, Chattopadhyay Arijit, Messina Sonia, Mercuri Eugenio, Laing Nigel G, Sewry Caroline A, Bydder Graeme, Muntoni Francesco. Magnetic resonance imaging of muscle in congenital myopathies associated with RYR1 mutations.. Neuromuscular disorders : NMD. 2004. DOI: 10.1016/j.nmd.2004.08.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.