MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ienj.2025.101712

Медицинская библиотека · International emergency nursing · 2025

An examination of how nurses' use of the Broselow tape affects patient safety during peripheral intravenous catheterization.

Alaca Aslı, Sarı Hatice Yıldırım

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Peripheral intravenous catheter insertion is one of the most common procedures in pediatric emergency departments. Inappropriate placement of a peripheral intravenous catheter and the associated management can lead to patient harm, which is considered a patient safety issue. The patient's safety could be compromised if a peripheral intravenous catheter is not properly placed and managed.

PURPOSE: This study was conducted to examine how nurses' use of the Broselow tape affects patient safety during peripheral intravenous catheterization.

MATERIALS AND

METHODS

In this study, the selection of peripheral intravenous catheters was based on a randomized controlled trial. The study was registered on ClinicalTrials.gov under the registration number NCT06165003. Using the Stepped Wedge design, data from the control group were collected first, followed by data from the experimental group. The two groups were compared on a variety of criteria, including the number of attempts, extravasation, accidental dislodgement, dwell time of catheter, and reasons for removal of catheter.

RESULTS

The study found no significant difference between the experimental and control groups in terms of "the nurses' success in performing the procedure" and "catheter dwell time" during peripheral intravenous catheterization. The patients' estimated weights in the experimental group were found to be consistent with both the Broselow tape estimates and parents' weight estimates.

CONCLUSIONS

The study indicates that using the Broselow tape for cannula selection during peripheral intravenous catheterization could serve as a novel alternative method.

Для цитирования: Alaca Aslı, Sarı Hatice Yıldırım. An examination of how nurses' use of the Broselow tape affects patient safety during peripheral intravenous catheterization.. International emergency nursing. 2025. DOI: 10.1016/j.ienj.2025.101712.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.