Hearing status in patients with rheumatoid arthritis.
Аннотация
OBJECTIVE
Rheumatoid arthritis is thought to induce conductive hearing loss and/or sensorineural hearing loss. This study evaluated the function of the middle ear and cochlea, and the related factors.
METHODS
Pure tone audiometry, speech reception thresholds, speech discrimination scores, tympanometry, acoustic reflexes, and distortion product otoacoustic emissions were assessed in rheumatoid arthritis patients and healthy volunteers.
RESULTS
Pure tone audiometry results revealed a higher bone conduction threshold in the rheumatoid arthritis group, but there was no significant difference when evaluated according to the sensorineural hearing loss definition. Distortion product otoacoustic emissions related prevalence of conductive or mixed hearing loss, tympanometry values, acoustic reflexes, and speech discrimination scores were not significantly different between the two groups. Sensorineural hearing loss was significantly more prevalent in patients who used azathioprine, cyclosporine and etanercept.
CONCLUSION
Higher bone conduction thresholds in some frequencies were detected in rheumatoid arthritis patients that were not clinically significant. Sensorineural hearing loss is significantly more prevalent in refractory rheumatoid arthritis patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.