DOI 10.1097/mao.0000000000001527

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2017

Audiometric Outcomes Following Endoscopic Ossicular Chain Reconstruction.

Yawn Robert J, Hunter Jacob B, O'Connell Brendan P, Wanna George B, Killeen Daniel E, Wick Cameron C, Isaacson Brandon, Rivas Alejandro

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the audiometric outcomes following endoscopic ossicular chain reconstruction (OCR).

STUDY

DESIGN

Retrospective case series.

SETTING

Two tertiary referral centers.

PATIENTS: Sixty two ears with ossicular discontinuity.

INTERVENTION(S): Endoscopic and microscopic OCR in patients with ossicular discontinuity.

MAIN OUTCOME MEASURES: Bone and air pure-tone averages (PTA), air-bone gap (ABG), and word recognition scores (WRS).

RESULTS

Sixty two ears were included for analysis. Patients that underwent ossiculoplasty were subdivided based on prosthesis type (total ossicular replacement prosthesis [TORP] and partial ossicular replacement prosthesis [PORP], primary and staged ossiculoplasties, and surgical approach [microscopic and total endoscopic]). Forty two ears required PORP reconstructions, while 20 ears required TORP reconstructions. The microscope was used to reconstruct the ossicular chain in 31 cases, while an exclusive endoscopic approach was used in the remaining 31 patients. Controlling for the prosthesis, there were no significant postoperative differences in bone PTA, air PTA, and ABG between primary and staged ossiculoplasties, or surgical approach.

CONCLUSIONS

Controlling for the type of prosthesis, there were no significant differences in hearing outcomes with respect to staged ossicular chain reconstruction or whether the endoscope or microscope was used for visualization. Thus, in this series, endoscopic OCR yields similar audiometric outcomes when compared with microscopic OCR.

Для цитирования: Yawn Robert J, Hunter Jacob B, O'Connell Brendan P, Wanna George B, Killeen Daniel E, Wick Cameron C, Isaacson Brandon, Rivas Alejandro. Audiometric Outcomes Following Endoscopic Ossicular Chain Reconstruction.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2017. DOI: 10.1097/mao.0000000000001527.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.