BACKGROUND

Hospital-acquired pressure injuries, including those related to airway devices, are a significant source of morbidity in critically ill patients.

OBJECTIVE

To determine the incidence of endotracheal tube-related pressure injuries in critically ill patients and to evaluate the effectiveness of interventions designed to prevent injury.

METHODS

MEDLINE, Embase, CINAHL, and the Cochrane Library were searched for studies of pediatric or adult patients in intensive care units that evaluated interventions to reduce endotracheal tube-related pressure injury. Reviewers extracted data on study and patient characteristics, incidence of pressure injury, type and duration of intervention, and outcomes. Risk of bias assessment followed the Cochrane Collaboration's criteria.

RESULTS

Twelve studies (5 randomized clinical trials, 3 quasi-experimental, 4 observational) representing 9611 adult and 152 pediatric patients met eligibility criteria. The incidence of pressure injury was 4.2% for orotracheal tubes and 21.1% for nasotracheal tubes. Interventions included anchor devices, serial endotracheal tube assessment or repositioning, and barrier dressings for nasotracheal tubes. Meta-analysis revealed that endotracheal tube stabilization was the most effective individual intervention for preventing pressure injury. Nasal alar barrier dressings decreased the incidence of skin or mucosal injury in patients undergoing nasotracheal intubation, and data on effectiveness of serial assessment and repositioning were inconclusive.

CONCLUSIONS

Airway device-related pressure injuries are common in critically ill patients, and patients with nasotracheal tubes are particularly susceptible to iatrogenic harm. Fastening devices and barrier dressings decrease the incidence of injury. Evidence regarding interventions is limited by lack of standardized assessments.

Для цитирования: Moser Chandler H, Peeler Anna, Long Robert, Schoneboom Bruce, Budhathoki Chakra, Pelosi Paolo P, Brenner Michael J, Pandian Vinciya. Prevention of Endotracheal Tube-Related Pressure Injury: A Systematic Review and Meta-analysis.. American journal of critical care : an official publication, American Association of Critical-Care Nurses. 2022. DOI: 10.4037/ajcc2022644.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.