Objective

To investigate the application value of intraoperative electrocochleography(ECochG) monitoring technique and insertion techniques in cochlear implant(CI) and analyze its relationship with postoperative residual hearing(RH) preservation.

Methods

Thirty-one patients(35 ears) who received CI in our hospital from June 2022 to July 2024 were enrolled. The Advanced Bionics Active Insertion Monitoring(AIM) system was used for real-time ECochG monitoring during surgery. Intraoperative cochlear microphonics (CM) waveform changes were recorded and analyzed in relation to postoperative RH preservation.

Results

①ECochG recordings were successfully obtained in 34 of 35 ears (97.1%). ②According to Harris classification, there were 7 ears(20.6%) of Type A(rising), 7 ears(20.6%) of Type C(declining), 8 ears(23.5%) of Type CC(fluctuating), and 12 ears(35.3%) of Type D(no response). ③The total CM amplitude decrease was significantly moderately correlated with postoperative low-mid frequency hearing loss(r=0.67, P=0.017). The total CM amplitude decrease was significantly moderately correlated with postoperative low frequency hearing loss(r=0.65, P=0.023). ④For the mean amplitude variation, the Amax was 30.70 μV, the Amin was 8.64 μV, and the Aend was 18.27 μV. ⑤Sixteen cases completed postoperative follow-up, with an average low-mid frequency(125-1 000 Hz) residual hearing loss of 15.25 dB HL and a RH preservation rate of 87.5%.

Conclusion

Intraoperative ECochG monitoring can effectively predict postoperative residual hearing changes, effectively guide surgical manipulation, and improve residual hearing preservation rate.

Для цитирования: Wang Ruijie, Luo Jianfen, Dai Qinglei, Chao Xiuhua, Ni Yifei, Hu Fangxia, Cao Yueran, Wang Haibo, Zhou Xiaohui, Xu Lei. [A clinical study of electrocochleography monitoring for residual hearing retention during minimally invasive cochlear implant].. Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery. 2025. DOI: 10.13201/j.issn.2096-7993.2025.05.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.