DOI 10.1097/iop.0b013e318295f9dd
Orbitomalar suspension with combined single drill hole canthoplasty.
Аннотация
PURPOSE: Whether resulting from a surgical complication or involutional change, lower eyelid retraction and canthal dystopia can lead to lagophthalmos and frank ectropion. The authors present their experience with a single drill hole fixation for both the lateral canthus and suborbicularis oculi fat for severe canthal dystopia and lower eyelid retraction.
METHODS
In this retrospective, consecutive study, the medical records of 13 patients who underwent single drill hole canthoplasty and suborbicularis oculi fat suspension were reviewed. A 4-0 nonabsorbable polypropylene suture was used to secure the canthal tendon, passed through a single lateral orbital rim drill hole from inside out. The suborbicularis oculi fat was then suspended in the same manner. Outcome measurements included linear marginal reflex distance 2, lagophthalmos, and subjective assessment of the results by the patient.
RESULTS
Preoperatively, the average linear marginal reflex distance 2 was 7.3 ± 1.0 mm, the average lagophthalmos was 3.5 ± 0.8 mm, and the average horizontal palpebral fissure width was 25.7 ± 1.3 mm. Postoperatively, average linear marginal reflex distance 2 was 5.3 ± 0.7 mm (p < 0.05), average lagophthalmos was 0.3 ± 0.4 mm (p < 0.05), and average horizontal palpebral fissure width was 30.2 ± 0.7 mm (p < 0.05). All patients noted symptomatic relief and were satisfied with the appearance of their eyelids at 6 months of follow up.
CONCLUSIONS
Single drill hole canthoplasty with suborbicularis oculi fat suspension is a viable alternative to previously described procedures. By using a single bony drill hole, rigid fixation is achieved with avoidance of multiple fixation points.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.