m+Medelevator.RU
← Поиск публикаций
Ophthalmology · 2010

Blink lagophthalmos and dry eye keratopathy in patients with non-facial palsy: clinical features and management with upper eyelid loading.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Patel Vikesh, Daya Sheraz M, Lake Damian, Malhotra Raman

Аннотация

PURPOSE: To evaluate the outcome of using upper eyelid gold weight implantation for patients with non-paralytic lagophthalmos on blink (LOB) only. We highlight the features of incomplete blink and reduced blink rate in patients with non-facial palsy as an exacerbating factor in dry eye keratopathy.

DESIGN: Retrospective, noncomparative case series.

PARTICIPANTS: Twelve patients (21 procedures) who underwent upper eyelid gold weight implantation for non-paralytic LOB only.

METHODS: Retrospective case note review of patients who underwent upper eyelid loading for non-paralytic LOB only over a 5-year period at a single institution.

MAIN OUTCOME MEASURES: Improvement in LOB, gentle and forced closure, increased frequency of blinking (FOB), degree of corneal staining, incidence of epithelial defects or corneal ulcer, improvement in vision, and subjective improvement in ocular discomfort.

RESULTS: Twenty-one procedures in 12 patients. Nine patients underwent bilateral surgery. Mean age was 56 (range, 8-80) years. Median postoperative follow-up was 15 months, and mean follow-up was 20.38 ± 16.61 (6-58) months. Eleven of 12 patients had an improvement in LOB and increased FOB, resulting in improvement of keratopathy and reduced ocular discomfort. One patient developed superior corneal thinning and descemetocele, requiring removal of the gold weight; 1 patient required ptosis surgery; and 1 patient developed a gold allergy and underwent platinum chain exchange.

CONCLUSIONS: We highlight the need to consider incomplete blink and reduced FOB as exacerbating factors for corneal-related disorders, including dry eye. Upper eyelid loading with gold weight implantation is a useful and predictive method of improving exposure-related keratopathy due to LOB in the absence of facial palsy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты