Complications and clinical analysis of 416 consecutive cochlear implantations.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Qiu Jianhua, Chen Yang, Tan Pei, Chen Jun, Han Yu, Gao Lei, Lu Yang, Du Bairu

Аннотация

OBJECTIVES: Cochlear implantation is a safe technique with a relatively low complication rate. However, certain complications may require specific attention to treat. The purpose of this study was to investigate complications of cochlear implantation for prevention and therapy.

STUDY DESIGN: Retrospective case series at a tertiary referral center in China.

METHODS: The patients (n=416) who received cochlear implants in our department between 2000 and 2010 were followed up (range, 3 months to 10 years). The complications were identified as "minor" or "major". All complications were systematically reviewed, and their causes were analyzed for prevention and therapy.

RESULTS: There were a total of 29 complications (7%). The minor were 23 cases (5.5%), including postoperative subcutaneous hematoma in 13 cases, acute otitis media in 2 cases, postoperative wound infection in 2 cases, delayed facial paralysis in 1 case, clonic facial spasm in 1 case, and severe vertigo in 4 cases. The major were 6 cases (1.5%), including cerebrospinal fluid leakage in 2 cases, implant-related infection and extrusion in 1 case, tympanic membrane perforation induced electrode exposed in 1 case, implantation failure due to cochlear ossification in 1 case, and magnet displacement in 1 case.

CONCLUSIONS: Although cochlear implantation is popular, it is essential to decrease the incidence of complications.