PURPOSE: To present the incidence, risk factors, and effect of opaque bubble layer (OBL) formation during flap creation in laser-assisted in situ keratomileusis (LASIK) with a 500-kHz femtosecond laser on visual performance.

METHODS

In this retrospective study, preoperative characteristics (age, sex, keratometric value, spherical equivalent, and central corneal thickness) and intraoperative surgical factors (used energy, docking type, and flap thickness) were compared between eyes with and without OBL formation during flap creation. Possible risk factors for specific types of OBLs were analyzed.

RESULTS

One hundred thirty-five eyes of 71 patients underwent LASIK, and OBL developed in 98 eyes (72.59%). In the univariate analysis, the greater than 80-µm flap group was associated with a lower OBL occurrence than the 80-µm flap group (P = .0424, odds ratio [OR] = 0.481) and hard docking was associated with increased OBL formation (P = .0001, OR = 6.859). In the multivariate analysis, hard docking was a risk factor for OBL development (P = .0003, OR = 6.329). In the subgroup analysis, hard docking had a marginal effect on OBL occurrence in the 80-µm flap group (P = .086, OR = 3.564), but it had a strong effect in the greater than 80-µm flap group (P = .0018, OR = 10.210).

CONCLUSIONS

Hard docking is a risk factor for OBL development. However, hard docking had a small effect on OBL occurrence in the 80-µm flap group during LASIK. OBL formation did not affect visual performance. [J Refract Surg. 2019;35(9):583-589.].

Для цитирования: Lim Dong Hui, Hyun Joo, Shin Eunhae, Ko Byung-Woo, Chung Eui-Sang, Chung Tae-Young. Incidence and Risk Factors of Opaque Bubble Layer Formation According to Flap Thickness During 500-kHz FS-LASIK.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2019. DOI: 10.3928/1081597x-20190814-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.