m+Medelevator.RU
← Поиск публикаций
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2016

Comparing audiological test results obtained from a sound processor attached to a Softband with direct and magnetic passive bone conduction hearing implant systems.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kara Ahmet, Iseri Mete, Durgut Merve, Topdag Murat, Ozturk Murat

Аннотация

The aim of this study was to compare audiological test results obtained from a sound processor (SP) attached to a Softband with those obtained from direct (abutment connection) bone conduction implant systems and magnetic passive bone conduction implant systems with different magnet strengths on patients implanted at our clinic. Twenty-four patients who were implanted with either an abutment or magnetic bone conduction implant system between January 2012 and December 2014 were analyzed for hearing results, such as free-field hearing thresholds, direct bone conduction hearing thresholds, and speech discrimination scores with aided and unaided conditions Both magnetic and direct osseointegrated bone conduction implant systems, as well as the Softband system, provide good hearing outcomes when compared with unaided performance; however, the abutment connection system gives better hearing thresholds in the higher frequencies. No significant difference in hearing gain was found between the Softband system, magnet 5, and magnet used by the patient. Magnetic and direct bone conduction hearing implant systems are both effective for rehabilitation of conductive and mixed hearing loss when conventional hearing aids cannot be used. However, patients with high-frequency hearing loss may be better suited to an abutment connection system if they are not satisfied with high-frequency hearing gains provided via the trial Softband system preoperatively and should be counseled accordingly.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты