DOI 10.1097/ijg.0000000000001000
Trabeculectomy Following Failed Ab Interno Gelatin Microstent: Case Series.
Аннотация
PURPOSE: The purpose of this study is to describe the outcomes of mitomycin C (MMC)-augmented trabeculectomy performed following a failed MMC-augmented XEN-45 implantation.
DESIGN
Retrospective case series.
METHODS
All consecutive cases of MMC-augmented trabeculectomy performed after MMC-augmented XEN-45 in the Glaucoma Service at Moorfields Eye Hospital between April 2015 and June 2017 were retrospectively reviewed.
RESULTS
We identified 8 patients who had a trabeculectomy following a failed XEN-45 implantation. The median intraocular pressure (IOP) before and after trabeculectomy was 29.0 mm Hg (12 to 45 mm Hg) and 7.5 mm Hg (2 to 12 mm Hg), respectively. At the last follow-up, 6 cases had a single-digit IOP and 2 of them developed hypotony-related complications (1 case of late choroidal detachment and 1 case of hypotony maculopathy). The median number of glaucoma drops and the median visual acuity (logMAR) before and after trabeculectomy were 2.5 (0 to 5), and 0 and 0.17 (0 to 0.3), and 0.3 (0.17 to 0.47), respectively. At the last follow-up, 3 cases showed an avascular bleb.
CONCLUSIONS
Trabeculectomy following a failed XEN-45 implantation seems technically feasible; however, higher than expected number of cases with low IOP and avascular blebs were observed. This might be related to the cumulative effect of MMC in these cases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.