Gastropexy device impaction in children with push percutaneous endoscopic gastrostomy.

Viart Juliette, Antoine Matthieu, Aumar Madeleine, Tran Léa Chantal, Guimber Dominique, Coopman Stéphanie, Saingier Clémence, Leroy Maxime, Ley Delphine, Gottrand Frédéric

СтатьяПеревод пока не подготовлен

Аннотация

One-step button percutaneous endoscopic gastrostomy (B-PEG) is a method for gastrostomy placement. Few studies have described complications associated with T-fasteners. This study aimed to assess the incidence and risk factors of post-gastrostomy T-bar retention. Children who underwent one-step button percutaneous endoscopic gastrostomy (B-PEG) placement in our tertiary center between 2009 and 2020 were included in this retrospective study. Patient characteristics, comorbidities, complications, and potential risk factors were analyzed. All post-procedure radiological examinations, T-bar numbers, and durations post-procedure were collected. T-bar retention was considered at least one T-bar after 6 weeks post-B-PEG. A total of 679 children (337 boys; median age at B-PEG, 1.7 years) were included. Among 483 patients with radiological examinations analyzed, 361 (74.7%) had at least one T-bar impaction at the first radiological examination (median time after B-PEG, 0.55 years). Younger age at B-PEG was a risk factor for T-bar impaction (odds ratio [OR]: 2.82, 95% confidence interval [CI]: [1.71-4.66], P < .0001). Nearly 75% of children presented T-bar impaction. These data indicate that to avoid gastropexy complications, discussion of early removal of T-fasteners post-B-PEG is warranted.

Для цитирования: Viart Juliette, Antoine Matthieu, Aumar Madeleine, Tran Léa Chantal, Guimber Dominique, Coopman Stéphanie, Saingier Clémence, Leroy Maxime, Ley Delphine, Gottrand Frédéric. Gastropexy device impaction in children with push percutaneous endoscopic gastrostomy.. Scientific reports. 2025. DOI: 10.1038/s41598-025-18169-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление