PURPOSE: To evaluate whether a discrepancy between the orientation of graft and recipient collagen lamellae can significantly limit the visual acuity after Descemet stripping automated endothelial keratoplasty (DSAEK).

METHODS

A multicenter cohort study of eyes that underwent DSAEK for Fuchs endothelial dystrophy or pseudophakic bullous keratopathy at Villa Serena-Villa Igea private Hospitals (Forlì, Italy) and at Santa Maria Nuova public hospital (Reggio Emilia, Italy), which were scheduled for a postoperative examination between July and September 2014. We have included eyes with a distance-corrected visual acuity of 8/10 or better, no ocular comorbidities, and a clear cornea. The main outcome measure was graft-recipient axis discrepancy of lamellar orientation around the visual axis as assessed by polarimetric interferometry.

RESULTS

Twelve eyes were included in this study. Eight eyes had a spectacle-corrected distance visual acuity of 8/10, 3 eyes had 9/10, and 1 eye had 10/10. In 8/12 (66.7%) eyes, 2 discernible axes of collagen lamellar orientation were identified and were all 30 degrees or more apart (range 30-90). In 2 eyes, only 1 axis was identified and in another 2 eyes, 2 axes 20 and 17 degrees apart were identified. The eye with 10/10 visual acuity presented a discrepancy of 17 degrees between lamellar axes.

CONCLUSIONS

A discrepancy between the lamellar orientation of the graft and the recipient is compatible with excellent visual acuity after DSAEK.

Для цитирования: Nahum Yoav, Iovieno Alfonso, Lipari Eugenio, Fonatana Luigi, Busin Massimo. Graft-Recipient Collagen Lamellar Axis Discrepancy Is Compatible With Excellent Visual Acuity After Descemet Stripping Automated Endothelial Keratoplasty.. Cornea. 2016. DOI: 10.1097/ico.0000000000000862.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.