DOI 10.1016/j.arcped.2005.05.005
[Evaluation of a new method for detection of obstructive disease in children asthma: the negative expiratory pressure (NEP)].
Аннотация
INTRODUCTION
To take in charge of an asthmatic child it is necessary to evaluate the lung function.
METHODS
In this study, the Negative Expiratory Pressure (NEP) has been used for the first time in children with asthma. After lung spirometry by plethysmography, we have used the NEP to assess the prevalence of expiratory flow limitation (FL) during resting breath in 27 asthmatic children (mean age: 11 +/- 2,5 years) 3-4 days after a crisis in both sitting and supine positions.
RESULTS
All the children presented an obstructive defect (FEV 1: 63 +/- 13% med) and a dynamic hyperinflation (FRC: 128 +/- 25% med). According to the NEP, 11 children presented an expiratory flow limitation (FL). Asthma was more severe in the FL than in non-FL children (GINA 2002 classification). Among the 11 FL children, 5 were FL in both sitting and supine position and 6 only in supine. Nine of the 27 children were FL with the conventional method. NEP seems a more accurate method to assess the clinical gravity of asthma than FEV 1. The reduction of FRC in the supine position probably explains the greater incidence of FL in supine position.
CONCLUSION
Because of its easy execution, NEP seems to be well adapted for children. Links between FL detected by NEP and clinical signs of asthma has to be assessed by furthers studies including more patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.