Value of blood flow velocity on color Doppler ultrasonography for optimization of delay in scanning time on computed tomography venography in patients with Budd-Chiari syndrome and inferior vena cava obstruction.
Аннотация
PURPOSE: To prospectively determine the value of blood flow velocity in the inferior vena cava (IVC) on color Doppler ultrasonography for the optimization of the delay in scanning time after contrast injection during computed tomography (CT) venography in patients with Budd-Chiari syndrome (BCS) with IVC obstruction.
METHODS
We enrolled 122 consecutive BCS patients with IVC obstruction. All patients underwent color Doppler ultrasonography, CT venography, and digital subtraction angiography (DSA) in that order prior to treatment. The delay in scanning time during CT venography was set at 120, 180, 240, and 300 s after contrast injection. The correlation between delay in CT scanning and IVC blood flow velocity on color Doppler ultrasonography was explored. Image quality was classified as good, moderate, or poor. Patients with good CT image quality were considered to have an optimal delay in scanning time.
RESULTS
Delays in scanning time of 120, 180, 240, and 300 s yielded good-quality images in 2, 7, 49, and 64 patients, respectively. The corresponding IVC blood flow velocities in these patients were 16.10 ± 0.42 cm/s (range 15.8-16.4 cm/s), 12.90 ± 1.58 cm/s (range, 11-15 cm/s), 7.53 ± 1.35 cm/s (range 5-10 cm/s), and 1.95 ± 1.75 cm/s (range 0-5.5 cm/s).
CONCLUSION
IVC blood flow velocity on color Doppler ultrasonography could serve as a useful tool for the optimization of the delay in scanning time during CT venography to ensure good-quality images for the diagnosis of BCS with IVC obstruction.